User guide

MPC5668EVB Users Manual Rev 0.1 May 2009
MPC5668EVBUM/D Page 25 of 29
5. Default Jumper Summary Table
The following table details the DEFAULT jumper configuration of the EVB as explained in detail in section 3.
Table 5-1 Default Jumper Positions
Jumper Default
Posn
PCB
Legend
Description
J1
LIN MOLEX – No Jumpers
J2
LIN MOLEX – No Jumpers
J3 (LIN
-
D
)
FITTED MASTER LIN D Bus Master Mode Enabled
J4 (
LIN D
)
FITTED LIN D RX LIN D RX from MCU Connected to LIN Interface
J5 (LIN
C
)
FITTED MASTER LIN C Bus Master Mode Enabled
J6 (SCI
-
PWR)
FITTED Power is applied to the SCI transceiver
J7 (FlexRAY)
FITTED CAP A DIS FlexRAY Decoupling CAP Disable
J8 (FlexRAY)
FITTED CAP A DIS FlexRAY Decoupling CAP Disable
J9 (FlexRAY)
FITTED CAP B DIS FlexRAY Decoupling CAP Disable
J10 (FlexRAY)
FITTED CAP B DIS FlexRAY Decoupling CAP Disable
J11
External Port No Jumpers
J12 (LIN
-
D
)
FITTED LIN D EN LIN D Bus Enable Physical Interface
J
13
(
LIN D
)
FITTED LIN D TX LIN D TX from MCU Connected to LIN Interface
J
14
(
LIN C
)
FITTED LIN C TX LIN C TX from MCU Connected to LIN Interface
J
15
(
LIN
C
)
FITTED LIN C RX LIN C RX from MCU Connected to LIN Interface
J
16
(
LIN C
)
FITTED LIN C EN LIN D Bus Enable Physical Interface
J17
(SCI A)
FITTED SCI A RX MCU RXD-A is routed to MAX3223
J18 (SCI A)
FITTED SCI A TX MCU TXD-A is routed to MAX3223
J
19
(Flex
-
A)
Posn 1-2
FITTED TX MCU PK4 is connected to FlexRay A transceiver TX
J19
(Flex
-
A)
Posn 3-4
FITTED TXEN MCU PK5 is connected to FlexRay A transceiver TXEN
J19
(Flex
-
A)
Posn 5-6
FITTED RX MCU PK3 is connected to Flexray A transceiver RXEN
J20
(CAN A)
Posn 1-2
FITTED WAKE CAN Transceiver WAKE is connected to GND
J20 (CAN A)
Posn 3-4
FITTED STB CAN Transceiver STB is connected to 5v
J20 (CAN A)
Posn 3-4
FITTED EN CAN Transceiver is Enabled
J21 (CAN B)
Posn 1-2
FITTED WAKE CAN Transceiver WAKE is connected to GND
J21 (CAN B)
Posn 3-4
FITTED STB CAN Transceiver STB is connected to 5v
J21 (CAN B)
Posn 3-4
FITTED EN CAN Transceiver is Enabled
J22
MLB Monitor No Jumpers
J23
(SCI
-
B)
FITTED TXD MCU TXD-B is routed via MAX3223
J24
(SCI
-
B)
FITTED RXD MCU RXD-B is routed via MAX3223
J25
(Flex
-
PWR)
Posn 1-2
FITTED 12V 12V Flexray circuitry is powered from main 12V input
J25
(Flex
-
PWR)
Posn 3-4
FITTED 5V 5V Flexray circuitry is powered from 5.0V switching reg
J
25
(Flex
-
PWR)
Posn 5-6
FITTED VIO VIO Flexray circuitry is powered from VDDE2