14 NXP Semiconductors
Figure 8. Camera module installation diagram
NOTE
If developers want to use Camera Module, R217, R218, R220, R221, R222, R223, R224, R225,
R226, R227, R228 and R229 should add 0 Ohm resistor.
2.15. User Interface Switch
There are four user interface switches on the MIMXRT1050 EVK Board. Their functionality is as
below.
2.15.1. Power Switch
SW1 is a slide switch to control the power of the MIMXRT1050 EVK Board when the power supply is
from J2. The function of this switch is listed below:
• Sliding the switch to the ON position connects the 5V power supply to the Evaluation board
main power system.
• Sliding the switch to OFF position immediately removes all power from the board.
2.15.2. ON/OFF Button
SW2 is the ON/OFF button for MIMXRT1050 EVK Board. A short pressing in OFF mode causes the
internal power management state machine to change state to ON. In ON mode, a short pressing
generates an interrupt (intended to be a software-controllable(power-down). An approximate 5 seconds
or more pressing causes a forced OFF. Both boot mode inputs can be disconnected.
2.15.3. Reset Button
There are two Reset Button on the EVK Board. SW3 is the Power Reset Button. Pressing the SW3 in the
Power On state will force to reset the system power except SNVS domain. The Processor will be
immediately turn off and reinitiate a boot cycle from the Processor Power Off state. SW4 is POR Reset
Button.
2.15.4. USER Button
SW8 is the USER Button(GPIO5-00) for developers using. Pressing can produce changes in high and
low levels.
2.16. Sensor
U32 on the EVK Board is a 6-Axis Ecompass (3-Axis Mag, 3-Axis Accel) sensor FXOS8700CQ. The
Ecompass is connected to i.MX RT1050 I2C1 port.