Datasheet

i.MX 6Dual/6Quad Automotive and Infotainment Applications Processors, Rev. 6, 11/2018
94 NXP Semiconductors
Electrical Characteristics
4.12.10 Image Processing Unit (IPU) Module Parameters
The purpose of the IPU is to provide comprehensive support for the flow of data from an image sensor
and/or to a display device. This support covers all aspects of these activities:
Connectivity to relevant devicescameras, displays, graphics accelerators, and TV encoders.
Related image processing and manipulation: sensor image signal processing, display processing,
image conversions, and other related functions.
Synchronization and control capabilities, such as avoidance of tearing artifacts.
IC9 Bus free time between a STOP and START condition 4.7 1.3 µs
IC10 Rise time of both I2Cx_SDA and I2Cx_SCL signals 1000 20 + 0.1C
b
4
300 ns
IC11 Fall time of both I2Cx_SDA and I2Cx_SCL signals 300 20 + 0.1C
b
4
300 ns
IC12 Capacitive load for each bus line (C
b
) 400 400 pF
1
A device must internally provide a hold time of at least 300 ns for I2Cx_SDA signal to bridge the undefined region of the falling
edge of I2Cx_SCL.
2
The maximum hold time has only to be met if the device does not stretch the LOW period (ID no IC5) of the I2Cx_SCL signal.
3
A Fast-mode I2C-bus device can be used in a Standard-mode I2C-bus system, but the requirement of Set-up time (ID No IC7)
of 250 ns must be met. This automatically is the case if the device does not stretch the LOW period of the I2Cx_SCL signal.
If such a device does stretch the LOW period of the I2Cx_SCL signal, it must output the next data bit to the I2Cx_SDA line
max_rise_time (IC9) + data_setup_time (IC7) = 1000 + 250 = 1250 ns (according to the Standard-mode I2C-bus specification)
before the I2Cx_SCL line is released.
4
C
b
= total capacitance of one bus line in pF.
Table 61. I
2
C Module Timing Parameters (continued)
ID Parameter
Standard Mode Fast Mode
Unit
Min Max Min Max