Datasheet

HEF4017B All information provided in this document is subject to legal disclaimers. © NXP B.V. 2011. All rights reserved.
Product data sheet Rev. 8 — 18 November 2011 5 of 18
NXP Semiconductors
HEF4017B
5-stage Johnson decade counter
7. Limiting values
Fig 6. Timing diagram
Table 4. Limiting values
In accordance with the Absolute Maximum Rating System (IEC 60134).
Symbol Parameter Conditions Min Max Unit
V
DD
supply voltage 0.5 +18 V
I
IK
input clamping current V
I
< 0.5 V or V
I
>V
DD
+ 0.5 V - 10 mA
V
I
input voltage 0.5 V
DD
+ 0.5 V
I
OK
output clamping current V
O
< 0.5 V or V
O
>V
DD
+ 0.5 V - 10 mA
I
I/O
input/output current - 10 mA