Datasheet
NXP Semiconductors
FRDM33772BSPIEVB
Featuring the MC33772B battery cell controller IC
FRDM33772BSPIEVBUG All information provided in this document is subject to legal disclaimers. © NXP B.V. 2018. All rights reserved.
User guide Rev. 1.0 — 22 June 2018
7 / 20
Figure 3. VCOM LED
The VCOM LED indicates when the device is in normal mode. Upon reset, the
MC33772B enters into normal mode (VCOM turns on). If there is no activity on the bus
after a timeout period of 60 seconds, the device enters low-power idle mode (VCOM
turns off). Once the device is initialized, if no communication occurs on the bus after one
second, the device resets and the LED turns off (VCOM off). Depending on the device
settings, the VCOM LED may flash 0.1...8 seconds during cyclic acquisition.
4.7 Test-point definitions
Figure 4 shows the location of the test points on the board.
Figure 4. Test points
The following test points provide access to various signals to and from the board.
Table 3. Test points
Test-point name Signal name Description
FAULT FAULT Measures the fault detection sent by the device
NEG_BAT GNDREF Ground reference of the device