Datasheet
5.2.2 Moisture handling ratings
Symbol Description Min. Max. Unit Notes
MSL Moisture sensitivity level — 3 — 1
1. Determined according to IPC/JEDEC Standard J-STD-020, Moisture/Reflow Sensitivity Classification for Nonhermetic
Solid State Surface Mount Devices.
5.2.3 ESD handling ratings
Symbol Description Min. Max. Unit Notes
V
HBM
Electrostatic discharge voltage, human body model -2000 +2000 V 1
V
CDM
Electrostatic discharge voltage, charged-device
model
-500 +500 V 2
I
LAT
Latch-up current at ambient temperature of 105°C -100 +100 mA 3
1. Determined according to JEDEC Standard JESD22-A114, Electrostatic Discharge (ESD) Sensitivity Testing Human
Body Model (HBM).
2. Determined according to JEDEC Standard JESD22-C101, Field-Induced Charged-Device Model Test Method for
Electrostatic-Discharge-Withstand Thresholds of Microelectronic Components.
3. Determined according to JEDEC Standard JESD78, IC Latch-Up Test.
5.2.4 Voltage and current operating ratings
Symbol Description Min. Max. Unit
V
DD
Digital supply voltage
1
–0.3 3.8 V
V
DDIO
V
DDIO
is an independent voltage supply for PORTE
2
–0.3 3.8 V
I
DD
Digital supply current — 300 mA
V
DIO
Digital input voltage (except RESET, EXTAL, and XTAL) –0.3 V
DD
+ 0.3 V
V
AIO
Analog
3
, RESET, EXTAL, and XTAL input voltage –0.3 V
DD
+ 0.3 V
I
D
Maximum current single pin limit (applies to all digital pins) –25 25 mA
V
DDA
Analog supply voltage V
DD
– 0.3 V
DD
+ 0.3 V
V
USB0_DP
USB0_DP input voltage –0.3 3.63 V
V
USB0_DM
USB0_DM input voltage –0.3 3.63 V
V
BAT
RTC battery supply voltage –0.3 3.8 V
1. It applies for all port pins.
2. V
DDIO
is independent of V
DD
domain and can operate at a voltage independent of V
DD
. However, it is required that V
DD
domain be powered up first prior to V
DDIO
. V
DDIO
must never be higher than V
DD
during power ramp up, or power down.
V
DD
and V
DDIO
may ramp together if tied to the same power supply.
Electrical characteristics
68
Kinetis KL82 Microcontroller, Rev. 3, 08/2016
NXP Semiconductors