Datasheet
74LV14 All information provided in this document is subject to legal disclaimers. © NXP B.V. 2011. All rights reserved.
Product data sheet Rev. 6 — 12 December 2011 5 of 19
NXP Semiconductors
74LV14
Hex inverting Schmitt trigger
10. Static characteristics
[1] Typical values are measured at T
amb
= 25 C.
Table 6. Static characteristics
Voltages are referenced to GND (ground = 0 V).
Symbol Parameter Conditions T
amb
= 40 C to +85 C T
amb
= 40 C
to +125 C
Unit
Min Typ
[1]
Max Min Max
V
OH
HIGH-level output voltage V
I
= V
T+
or V
T
I
O
= 100 A; V
CC
= 1.2 V - 1.2 - - - V
I
O
= 100 A; V
CC
= 2.0 V 1.8 2.0 - 1.8 - V
I
O
= 100 A; V
CC
= 2.7 V 2.5 2.7 - 2.5 - V
I
O
= 100 A; V
CC
= 3.0 V 2.8 3.0 - 2.8 - V
I
O
= 100 A; V
CC
= 4.5 V 4.3 4.5 - 4.3 - V
I
O
= 6 mA; V
CC
= 3.0 V 2.4 2.82 - 2.2 - V
I
O
= 12 mA; V
CC
= 4.5 V 3.6 4.2 - 3.5 - V
V
OL
LOW-level output voltage V
I
= V
T+
or V
T
I
O
= 100 A; V
CC
= 1.2 V - 0 - - - V
I
O
= 100 A; V
CC
= 2.0 V - 0 0.2 - 0.2 V
I
O
= 100 A; V
CC
= 2.7 V - 0 0.2 - 0.2 V
I
O
= 100 A; V
CC
= 3.0 V - 0 0.2 - 0.2 V
I
O
= 100 A; V
CC
= 4.5 V - 0 0.2 - 0.2 V
I
O
= 6 mA; V
CC
= 3.0 V - 0.25 0.40 - 0.50 V
I
O
= 12 mA; V
CC
= 4.5 V - 0.35 0.55 - 0.65 V
I
I
input leakage current V
I
=V
CC
or GND;
V
CC
=5.5V
- - 1.0 - 1.0 A
I
CC
supply current V
I
= V
CC
or GND; I
O
= 0 A;
V
CC
=5.5V
- - 20.0 - 40 A
I
CC
additional supply current per input; V
I
= V
CC
0.6 V;
V
CC
= 2.7 V to 3.6 V
--500-850A
C
I
input capacitance - 3.5 - - - pF