Datasheet

2003 May 16 7
Philips Semiconductors Product specification
Dual 4-channel analog multiplexer,
demultiplexer
74HC4052; 74HCT4052
RECOMMENDED OPERATING CONDITIONS
SYMBOL PARAMETER CONDITIONS
74HC4052 74HCT4052
UNIT
MIN. TYP. MAX. MIN. TYP. MAX.
V
CC
supply voltage see Figs 7 and 8
V
CC
GND 2.0 5.0 10.0 4.5 5.0 5.5 V
V
CC
V
EE
2.0 5.0 10.0 2.0 5.0 10.0 V
V
I
input voltage GND V
CC
GND V
CC
V
V
S
switch voltage V
EE
V
CC
V
EE
V
CC
V
T
amb
operating ambient
temperature
see DC and AC
characteristics per
device
40 +25 +85 40 +25 +85 °C
40 +125 40 +125 °C
t
r
, t
f
input rise and fall times V
CC
= 2.0 V 6.0 1000 6.0 500 ns
V
CC
= 4.5 V 6.0 500 6.0 500 ns
V
CC
= 6.0 V 6.0 400 6.0 500 ns
V
CC
= 10.0 V 6.0 250 6.0 500 ns
handbook, halfpage
04 12
12
0
4
8
8
MNB044
operating area
V
CC
GND
(V)
V
CC
V
EE
(V)
Fig.7 Guaranteed operating area as a function of
the supply voltages for 74HC4052.
handbook, halfpage
0
12
6
10
8
2
4
04 128
MNB045
operating area
V
CC
GND
(V)
V
CC
V
EE
(V)
Fig.8 Guaranteed operating area as a function of
the supply voltages for 74HCT4052.