Datasheet
2003 May 16 15
Philips Semiconductors Product specification
Dual 4-channel analog multiplexer,
demultiplexer
74HC4052; 74HCT4052
Type 74HCT4052
GND = 0 V; t
r
=t
f
= 6 ns; C
L
=50pF.
Note
1. All typical values are measured at T
amb
=25°C.
SYMBOL PARAMETER
TEST CONDITIONS
MIN. TYP. MAX. UNIT
OTHER V
CC
(V) V
EE
(V)
T
amb
= −40 to +85 °C; note 1
t
PHL
/t
PLH
propagation delay V
is
to V
os
R
L
= ∞; see Fig.19 4.5 0 − 515ns
4.5 −4.5 − 410ns
t
PZH
/t
PZL
turn-on time E, Sn to V
os
R
L
=1kΩ; see Figs 20,
22 and 21
4.5 0 − 41 88 ns
4.5 −4.5 − 28 60 ns
t
PHZ
t
PLZ
turn-off time E, Sn to V
os
R
L
=1kΩ; see Figs 20,
22 and 21
4.5 0 − 26 63 ns
4.5 −4.5 − 21 48 ns
T
amb
= −40 to +125 °C
t
PHL
/t
PLH
propagation delay V
is
to V
os
R
L
= ∞; see Fig.19 4.5 0 −−18 ns
4.5 −4.5 −−12 ns
t
PZH
/t
PZL
turn-on time E, Sn to V
os
R
L
=1kΩ; see Figs 20,
22 and 21
4.5 0 −−105 ns
4.5 −4.5 −−72 ns
t
PHZ
/t
PLZ
turn-off time E, Sn to V
os
R
L
=1kΩ; see Figs 20,
22 and 21
4.5 0 −−75 ns
4.5 −4.5 −−57 ns