Datasheet

Table Of Contents
Advance Information MC68HC908GP20Rev 2.1
116 Freescale Semiconductor
P, the power of two multiplier, and N, the range multiplier, are
integers.
In cases where desired bus frequency has some tolerance,
choose f
RCLK
to a value determined either by other module
requirements (such as modules which are clocked by CGMXCLK),
cost requirements, or ideally, as high as the specified range
allows. See Section 23. Preliminary Electrical Specifications.
Choose the reference divider, R = 1. After choosing N and P, the
actual bus frequency can be determined using equation in 2
above.
When the tolerance on the bus frequency is tight, choose f
RCLK
to
an integer divisor of f
BUSDES
, and R = 1. If f
RCLK
cannot meet this
requirement, use the following equation to solve for R with
practical choices of f
RCLK
, and choose the f
RCLK
that gives the
lowest R.
4. Select a VCO frequency multiplier, N.
Reduce N/R to the lowest possible R.
5. If N is < N
max
, use P = 0. If N > N
max
, choose P using this table:
Current N Value P
0
1
2
3
R round R
MAX
f
VCLKDES
f
RCLK
--------------------------



integer
f
VCLKDES
f
RCLK
--------------------------






×=
N round
Rf
VCLKDES
×
f
RCLK
-------------------------------------



=
0N<N
max
N
max
N<N
max
2×
N
max
2× N<N
max
4×
N
max
4× N<N
max
8×