Datasheet
Analog Integrated Circuit Device Data
44 Freescale Semiconductor
07XSC200
5.4.4.10 Default Device Configuration
The default device configuration is explained by the following:
• HS output is commanded by the corresponding IN input or On bit through the SPI. The medium slew-rate is used,
• HS output is fully protected by the Xenon overcurrent profile by default, the severe short-circuit protection, the undervoltage
and the overtemperature protection. The auto-retry feature is enabled,
• OpenLoad in ON and OFF state and HS shorted to V
PWR
detections are available,
• No current recopy and no analog temperature feedback active,
• Overvoltage protection is enabled,
• SO reporting fault status must be ignored,
•V
DD
failure detection is disabled.