Datasheet
Analog Integrated Circuit Device Data
18 Freescale Semiconductor
07XSC200
SPI INTERFACE CHARACTERISTICS
(36)
Maximum Frequency of SPI Operation
f
SPI
– – 8.0 MHz
Required Low State Duration for RSTB
(37)
t
WRSTB
10 – – s
Rising Edge of CSB to Falling Edge of CSB (Required Setup Time)
(38)
t
CSB
– – 1.0 s
Rising Edge of RSTB to Falling Edge of CSB (Required Setup Time)
(38)
t
ENBL
– – 5.0 s
Falling Edge of CSB to Rising Edge of SCLK (Required Setup Time)
(38)
t
LEAD
– – 500 ns
Required High State Duration of SCLK (Required Setup Time)
(38)
t
WSCLKh
– – 50 ns
Required Low State Duration of SCLK (Required Setup Time)
(38)
t
WSCLKl
– – 50 ns
Falling Edge of SCLK to Rising Edge of CSB (Required Setup Time)
(38)
t
LAG
– – 60 ns
SI to Falling Edge of SCLK (Required Setup Time)
(39)
t
SI (SU)
– – 37 ns
Falling Edge of SCLK to SI (Required Setup Time)
(39)
t
SI (HOLD)
– – 49 ns
SO Rise Time
•C
L
= 80 pF
t
RSO
– – 13
ns
SO Fall Time
•C
L
= 80 pF
t
FSO
– – 13
ns
SI, CSB, SCLK, Incoming Signal Rise Time
(39)
t
RSI
– – 13 ns
SI, CSB, SCLK, Incoming Signal Fall Time
(39)
t
FSI
– – 13 ns
Time from Falling Edge of CSB to SO Low-impedance
(40)
t
SO(EN)
– – 60 ns
Time from Rising Edge of CSB to SO High-impedance
(41)
t
SO(DIS)
– – 60 ns
Notes
36. Parameters guaranteed by design.
37. RSTB low duration measured with outputs enabled and going to OFF or disabled condition.
38. Maximum setup time required for the 07XSC200 is the minimum guaranteed time needed from the microcontroller.
39. Rise and Fall time of incoming SI, CSB, and SCLK signals suggested for design consideration to prevent the occurrence of double
pulsing.
40. Time required for output status data to be available for use at SO. 1.0 kon pull-up on CSB.
41. Time required for output status data to be terminated at SO. 1.0 kon pull-up on CSB.
Table 4. Dynamic Electrical Characteristics (continued)
Characteristics noted under conditions 6.0 V V
PWR
20 V, 3.0 V V
DD
5.5 V, - 40 C T
A
125 C, GND = 0 V unless
otherwise noted. Typical values noted reflect the approximate parameter means at T
A
= 25 °C under nominal conditions unless
otherwise noted.
Characteristic Symbol Min Typ Max Unit