7.2.1 Noise rejection
Impulse noise coupled into the I
2
C-bus/SMBus signals can prevent the I
2
C-bus/SMBus
bus from operating reliably. The hostile signals may appear on the SCL line, SDA line, or
both. Impulse noise may also enter the common ground connection, or be caused by
current in the ground path caused by DC power supplies, or other signals sharing the
common ground return path. This problem is removed by using a differential transmission
line, in place of the I
2
C-bus/SMBus signal path. The dI
2
C-bus receiver (at each dI
2
C-bus
node) subtracts the signals on the two differential lines (D+ and D), and eliminates any
common-mode noise that is coupled into the dI
2
C-bus. The receiver amplifies the signals
which are also attenuated by the bulk resistance of the transmission line cable
connection, and does not rely on a common ground connection at each node.
7.2.2 Rejection of ground offset voltage
Hostile signals interfere with the I
2
C-bus/SMBus bus through the common ground
connection between each node. Current in this ground path causes an offset that may
cause false data or push the I
2
C-bus/SMBus signals outside of an acceptable range.
Unwanted ground offset can be caused by heavy DC current in the ground path, or
injection of ground current from AC signals, either of which may show up as false signals.
Because the dI
2
C-bus node’s receiver responds only to the difference between the two
dI
2
C-bus transmission lines, common-mode signals are ignored. There is no need to have
a ground connection between each of the nodes, which may be powered locally. Nodes
may also be powered by extra conductors (for V
DD
and ground) run with the dI
2
C-bus
signals. Voltage offsets caused by DC current in these additional wires are ignored by the
dI
2
C-bus receiver, which subtracts the two differential signals (D+ and D).
7.3 EN pin
The EN pin places the PCA9614 in an idle state, effectively stopping transmission of
I
2
C-bus/SMBus traffic (data) over the dI
2
C-bus. An internal pull-up holds the device
enabled. The enable pin is used to isolate a badly behaved slave on power-up until after
the system power-up reset. It should never change state during an I
2
C-bus/SMBus
operation because disabling during a bus operation hangs the bus and enabling part way
through a bus cycle could confuse the I
2
C-bus/SMBus parts being enabled. The EN pin
should only change state when the global bus and the buffer port are in an idle state to
prevent system failures. The EN pin turns on or off both channels.
Fig 5. dI
2
C-bus terminations
DxxxP
DxxxM
aaa-011061
twisted-pair cable
DxxxP
DxxxM