Datasheet
MPXV5004G
Sensors
Freescale Semiconductor 3
Pressure
Operating Characteristics
Table 1. Operating Characteristics (V
S
= 5.0 V
DC
, T
A
= 25°C unless otherwise noted, P1 > P2)
Characteristic Symbol Min Typ Max Units
Pressure Range
P
OP
0 — 3.92
400
kPa
mm H
2
O
Supply Voltage
(1)
1. Device is ratiometric within this specified excitation range.
V
S
4.75 5.0 5.25 V
DC
Supply Current
I
S
— — 10 mAdc
Span @ 306 mm H
2
O (3 kPa)
(2)
Full Scale Span @ 400 mm H
2
O (3.92 kPa)
(2)
2. Span is defined as the algebraic difference between the output voltage at specified pressure and the output voltage at the minimum rated
pressure.
V
FSS
—
—
3.0
4.0
—
—
V
Offset
(3)
3. Offset (V
off
) is defined as the output voltage at the minimum rated pressure.
V
OFF
0.75 1.0 1.25 V
Sensitivity
V/P — 1.0 — V/kPa
Accuracy
(4) (5)
0 to 100 mm H
2
O (10 to 60°C)
100 to 400 mm H
2
O (10 to 60°C)
0 to 400 mm H
2
O (10 to 60°C
4. Accuracy (error budget) consists of the following:
Linearity:Output deviation from a straight line relationship with pressure over the specified pressure range.
Temperature Hysteresis:Output deviation at any temperature within the operating temperature range, after the temperature is cycled to and
from the minimum or maximum operating temperature points, with zero differential pressure applied.
Pressure Hysteresis:Output deviation at any pressure within the specified range, when this pressure is cycled to and from the minimum or
maximum rated pressure, at 25°C.
Offset Stability:Output deviation, after 1000 temperature cycles, -30 to 100°C, and 1.5 million pressure cycles, with minimum rated pressure
applied.
TcSpan:Output deviation over the temperature range of 10 to 60°C, relative to 25°C.
TcOffset:Output deviation with minimum rated pressure applied, over the temperature range of 10 to 60
°
C, relative to 25
°
C.
Variation from Nominal:The variation from nominal values, for Offset or Full Scale Span, as a percent of V
FSS
, at 25°C.
5. Auto Zero at Factory Installation: Due to the sensitivity of the MPVZ5004G, external mechanical stresses and mounting position can affect
the zero pressure output reading. Autozeroing is defined as storing the zero pressure output reading and subtracting this from the device's
output during normal operations. Reference AN1636 for specific information. The specified accuracy assumes a maximum temperature
change of ±5°C between autozero and measurement.
—
—
—
—
—
—
—
—
—
±1.5
±2.5
±6.25
%V
FSS
with auto
zero
%V
FSS
with auto
zero
%V
FSS
without
auto zero