Datasheet
MPX2200
Sensors
Freescale Semiconductor 3
Pressure
Maximum Ratings
Voltage Output versus Applied Differential
The output voltage of the differential or gauge sensor
increases with increasing pressure applied to the pressure
side (P1) relative to the vacuum side (P2). Similarly, output
voltage increases as increasing vacuum is applied to the
vacuum side (P2) relative to the pressure side (P1).
Figure 1 shows a block diagram of the internal circuitry on
the stand-alone pressure sensor chip.
Figure 1. Temperature Compensated and Calibrated
Pressure Sensor Schematic
Table 2. Maximum Ratings
(1)
1. Exposure beyond the specified limits may cause permanent damage or degradation to the device.
Rating Max Value Unit
Maximum Pressure (P1 > P2)
800 kPa
Storage Temperature
–40 to +125 °C
Operating Temperature
–40 to +125 °C
+V
OUT
–V
OUT
4
2
V
S
3
Sensing
Element
GND
1
Thin Film
Temperature
Compensation
and Calibration