Datasheet

MPX2102
Sensors
4 Freescale Semiconductor, Inc.
Pressure
Maximum Ratings
Voltage Output vs. Applied Differential
The differential voltage output of the sensor is directly
proportional to the differential pressure applied.
The absolute sensor has a built-in reference vacuum. The
output voltage will decrease as vacuum, relative to ambient,
is drawn on the pressure (P1) side.
The output voltage of the differential or gauge sensor
increases with increasing pressure applied to the pressure
(P1) side relative to the vacuum (P2) side. Similarly, output
voltage increases as increasing vacuum is applied to the
vacuum (P2) side relative to the pressure (P1) side.
Figure 1 illustrates a block diagram of the internal circuitry
on the stand-alone pressure sensor chip.
Figure 1. Temperature Compensated Pressure Sensor Schematic
Table 2. Maximum Ratings
(1)
1. Exposure beyond the specified limits may cause permanent damage or degradation to the device.
Rating Symbol Value Unit
Maximum Pressure (P1 > P2) P
MAX
400 kPa
Storage Temperature T
STG
-40 to +125 °C
Operating Temperature T
A
-40 to +125 °C
2
4
1
Thin Film
Temperature
Compensation
and
Calibration
Circuitry
GND
3
V
S
+ V
OUT
- V
OUT
X-ducer
Sensing
Element