Datasheet
MPX10
Sensors
Freescale Semiconductor 3
Pressure
Maximum Ratings
Figure 1 shows a schematic of the internal circuitry on the stand-alone pressure sensor chip.
Figure 1. Uncompensated Pressure Sensor Schematic
Voltage Output versus Applied Differential Pressure
The output voltage of the differential or gauge sensor
increases with increasing pressure applied to the pressure
side (P1) relative to the vacuum side (P2). Similarly, output
voltage increases as increasing vacuum is applied to the
vacuum side (P2) relative to the pressure side (P1).
Table 2. Maximum Ratings
(1)
1. Exposure beyond the specified limits may cause permanent damage or degradation to the device.
Rating Symbol Value Unit
Maximum Pressure (P1 > P2) P
MAX
75 kPa
Burst Pressure (P1 > P2) P
BURST
100 kPa
Storage Temperature T
STG
–40 to +125 °C
Operating Temperature T
A
–40 to +125 °C
1
2
3
4
GND
+V
OUT
–V
OUT
+V
S
Sensing
Element