Datasheet

MPC8308 PowerQUICC II Pro Processor Hardware Specification, Rev. 3
54 Freescale Semiconductor
I
2
C
This figure provides the AC test load for the I
2
C.
Figure 45. I
2
C AC Test Load
This figure shows the AC timing diagram for the I
2
C bus.
Figure 46. I
2
C Bus AC Timing Diagram
Setup time for STOP condition t
I2PVKH
0.6 s
Bus free time between a STOP and START condition t
I2KHDX
1.3 s
Noise margin at the LOW level for each connected device (including hysteresis) V
NL
0.1 NV
DD
—V
Noise margin at the HIGH level for each connected device (including hysteresis) V
NH
0.2 NV
DD
—V
Notes:
1. The symbols used for timing specifications follow the pattern of t
(first two letters of functional block)(signal)(state) (reference)(state)
for
inputs and t
(first two letters of functional block)(reference)(state)(signal)(state)
for outputs. For example, t
I2DVKH
symbolizes I
2
C timing (I2)
with respect to the time data input signals (D) reach the valid state (V) relative to the t
I2C
clock reference (K) going to the high
(H) state or setup time. Also, t
I2SXKL
symbolizes I
2
C timing (I2) for the time that the data with respect to the start condition (S)
went invalid (X) relative to the t
I2C
clock reference (K) going to the low (L) state or hold time. Also, t
I2PVKH
symbolizes I
2
C timing
(I2) for the time that the data with respect to the stop condition (P) reaching the valid state (V) relative to the t
I2C
clock reference
(K) going to the high (H) state or setup time. For rise and fall times, the latter convention is used with the appropriate letter: R
(rise) or F (fall).
2. The device provides a hold time of at least 300 ns for the SDA signal (referred to the V
IHmin
of the SCL signal) to bridge the
undefined region of the falling edge of SCL.
3. The maximum t
I2DXKL
has only to be met if the device does not stretch the LOW period (t
I2CL
) of the SCL signal.
4. C
B
= capacitance of one bus line in pF.
5. The device does not follow the I
2
C-BUS Specifications, Version 2.1, regarding the t
I2CF
AC parameter.
Table 44. I
2
C AC Electrical Specifications (continued)
All values refer to V
IH
(min) and V
IL
(max) levels (see Ta bl e 4 3).
Parameter Symbol
1
Min Max Unit
Output
Z
0
= 50
NV
DD
/2
R
L
= 50
SrS
SDA
SCL
t
I2CF
t
I2SXKL
t
I2CL
t
I2CH
t
I2DXKL
t
I2DVKH
t
I2SXKL
t
I2SVKH
t
I2KHKL
t
I2PVKH
t
I2CR
t
I2CF
PS