Datasheet

Electrical and Thermal Characteristics
MPC5200 Data Sheet, Rev. 4
Freescale Semiconductor 61
3.3.16 GPIOs and Timers
3.3.16.1 General and Asynchronous Signals
The MPC5200 contains several sets if I/Os that do not require special setup, hold, or valid requirements.
Most of these are asynchronous to the system clock. The following numbers are provided for test and
validation purposes only, and they assume a 133 MHz internal bus frequency.
Figure 46 shows the GPIO Timing Diagram. Table 50 gives the timing specifications.
Figure 46. Timing Diagram—Asynchronous Signals
Table 50. Asynchronous Signals
Sym Description Min Max Units SpecID
t
CK
Clock Period 7.52 ns A16.1
t
IS
Input Setup for Async Signal 12 ns A16.2
t
IH
Input Hold for Async Signals 1 ns A16.3
t
DV
Output Valid 15.33 ns A16.4
t
DH
Output Hold 1 ns A16.5
Output
Input
t
CK
valid
valid
t
DV
t
DH
t
IS
t
IH