Datasheet

Table Of Contents
MSCAN
MC9S12DP256 — Revision 1.1
MSCAN
SYNC_SEG: This segment has a fixed length of one time
quantum. Signal edges are expected to happen within this section.
Time Segment 1: This segment includes the PROP_SEG and the
PHASE_SEG1 of the CAN standard. It can be programmed by
setting the parameter TSEG1 to consist of 4 to 16 time quanta.
Time Segment 2: This segment represents the PHASE_SEG2 of
the CAN standard. It can be programmed by setting the TSEG2
parameter to be 2 to 8 time quanta long.
Figure 100 Segments within the Bit Time
1. For further explanation of the under-lying concepts please refer to ISO/DIS 11519-1, Section
10.3.
2. Reference the Bosch CAN 2.0A/B protocol specification dated September 1991 for bit timing.
Bit Rate
f
Tq
number of Time Quanta◊◊ ()
---------------------------------------------------------------------------------=
SYNC_SEG
Time Segment 1 Time Segment 2
1 4 ... 16 2 ... 8
8 ... 25 Time Quanta
= 1 Bit Time
NRZ Signal
Sample Point
(single or triple sampling)
(PROP_SEG + PHASE_SEG1) (PHASE_SEG2)
Transmit Point