Datasheet
Table Of Contents
- Chapter 1 Device Overview
- Chapter 2 Pins and Connections
- Chapter 3 Modes of Operation
- Chapter 4 Memory
- 4.1 MC9S08DN60 Series Memory Map
- 4.2 Reset and Interrupt Vector Assignments
- 4.3 Register Addresses and Bit Assignments
- 4.4 RAM
- 4.5 Flash and EEPROM
- 4.5.1 Features
- 4.5.2 Program and Erase Times
- 4.5.3 Program and Erase Command Execution
- 4.5.4 Burst Program Execution
- 4.5.5 Sector Erase Abort
- 4.5.6 Access Errors
- 4.5.7 Block Protection
- 4.5.8 Vector Redirection
- 4.5.9 Security
- 4.5.10 EEPROM Mapping
- 4.5.11 Flash and EEPROM Registers and Control Bits
- 4.5.11.1 Flash and EEPROM Clock Divider Register (FCDIV)
- 4.5.11.2 Flash and EEPROM Options Register (FOPT and NVOPT)
- 4.5.11.3 Flash and EEPROM Configuration Register (FCNFG)
- 4.5.11.4 Flash and EEPROM Protection Register (FPROT and NVPROT)
- 4.5.11.5 Flash and EEPROM Status Register (FSTAT)
- 4.5.11.6 Flash and EEPROM Command Register (FCMD)
- Chapter 5 Resets, Interrupts, and General System Control
- 5.1 Introduction
- 5.2 Features
- 5.3 MCU Reset
- 5.4 Computer Operating Properly (COP) Watchdog
- 5.5 Interrupts
- 5.6 Low-Voltage Detect (LVD) System
- 5.7 MCLK Output
- 5.8 Reset, Interrupt, and System Control Registers and Control Bits
- 5.8.1 Interrupt Pin Request Status and Control Register (IRQSC)
- 5.8.2 System Reset Status Register (SRS)
- 5.8.3 System Background Debug Force Reset Register (SBDFR)
- 5.8.4 System Options Register 1 (SOPT1)
- 5.8.5 System Options Register 2 (SOPT2)
- 5.8.6 System Device Identification Register (SDIDH, SDIDL)
- 5.8.7 System Power Management Status and Control 1 Register (SPMSC1)
- 5.8.8 System Power Management Status and Control 2 Register (SPMSC2)
- Chapter 6 Parallel Input/Output Control
- 6.1 Port Data and Data Direction
- 6.2 Pull-up, Slew Rate, and Drive Strength
- 6.3 Pin Interrupts
- 6.4 Pin Behavior in Stop Modes
- 6.5 Parallel I/O and Pin Control Registers
- 6.5.1 Port A Registers
- 6.5.1.1 Port A Data Register (PTAD)
- 6.5.1.2 Port A Data Direction Register (PTADD)
- 6.5.1.3 Port A Pull Enable Register (PTAPE)
- 6.5.1.4 Port A Slew Rate Enable Register (PTASE)
- 6.5.1.5 Port A Drive Strength Selection Register (PTADS)
- 6.5.1.6 Port A Interrupt Status and Control Register (PTASC)
- 6.5.1.7 Port A Interrupt Pin Select Register (PTAPS)
- 6.5.1.8 Port A Interrupt Edge Select Register (PTAES)
- 6.5.2 Port B Registers
- 6.5.2.1 Port B Data Register (PTBD)
- 6.5.2.2 Port B Data Direction Register (PTBDD)
- 6.5.2.3 Port B Pull Enable Register (PTBPE)
- 6.5.2.4 Port B Slew Rate Enable Register (PTBSE)
- 6.5.2.5 Port B Drive Strength Selection Register (PTBDS)
- 6.5.2.6 Port B Interrupt Status and Control Register (PTBSC)
- 6.5.2.7 Port B Interrupt Pin Select Register (PTBPS)
- 6.5.2.8 Port B Interrupt Edge Select Register (PTBES)
- 6.5.3 Port C Registers
- 6.5.4 Port D Registers
- 6.5.4.1 Port D Data Register (PTDD)
- 6.5.4.2 Port D Data Direction Register (PTDDD)
- 6.5.4.3 Port D Pull Enable Register (PTDPE)
- 6.5.4.4 Port D Slew Rate Enable Register (PTDSE)
- 6.5.4.5 Port D Drive Strength Selection Register (PTDDS)
- 6.5.4.6 Port D Interrupt Status and Control Register (PTDSC)
- 6.5.4.7 Port D Interrupt Pin Select Register (PTDPS)
- 6.5.4.8 Port D Interrupt Edge Select Register (PTDES)
- 6.5.5 Port E Registers
- 6.5.6 Port F Registers
- 6.5.7 Port G Registers
- 6.5.1 Port A Registers
- Chapter 7 Central Processor Unit (S08CPUV3)
- 7.1 Introduction
- 7.2 Programmer’s Model and CPU Registers
- 7.3 Addressing Modes
- 7.4 Special Operations
- 7.5 HCS08 Instruction Set Summary
- Chapter 8 Multi-Purpose Clock Generator (S08MCGV1)
- 8.1 Introduction
- 8.2 External Signal Description
- 8.3 Register Definition
- 8.4 Functional Description
- 8.4.1 Operational Modes
- 8.4.1.1 FLL Engaged Internal (FEI)
- 8.4.1.2 FLL Engaged External (FEE)
- 8.4.1.3 FLL Bypassed Internal (FBI)
- 8.4.1.4 FLL Bypassed External (FBE)
- 8.4.1.5 PLL Engaged External (PEE)
- 8.4.1.6 PLL Bypassed External (PBE)
- 8.4.1.7 Bypassed Low Power Internal (BLPI)
- 8.4.1.8 Bypassed Low Power External (BLPE)
- 8.4.1.9 Stop
- 8.4.2 Mode Switching
- 8.4.3 Bus Frequency Divider
- 8.4.4 Low Power Bit Usage
- 8.4.5 Internal Reference Clock
- 8.4.6 External Reference Clock
- 8.4.7 Fixed Frequency Clock
- 8.4.1 Operational Modes
- 8.5 Initialization / Application Information
- 8.5.1 MCG Module Initialization Sequence
- 8.5.2 MCG Mode Switching
- 8.5.2.1 Example # 1: Moving from FEI to PEE Mode: External Crystal = 4 MHz, Bus Frequency = 8 MHz
- 8.5.2.2 Example # 2: Moving from PEE to BLPI Mode: External Crystal = 4 MHz, Bus Frequency =16 kHz
- 8.5.2.3 Example #3: Moving from BLPI to FEE Mode: External Crystal = 4 MHz, Bus Frequency = 16 MHz
- 8.5.2.4 Example # 4: Moving from FEI to PEE Mode: External Crystal = 8 MHz, Bus Frequency = 8 MHz
- 8.5.3 Calibrating the Internal Reference Clock (IRC)
- Chapter 9 Analog Comparator (S08ACMPV3)
- Chapter 10 Analog-to-Digital Converter (S08ADC12V1)
- 10.1 Introduction
- 10.2 External Signal Description
- 10.3 Register Definition
- 10.3.1 Status and Control Register 1 (ADCSC1)
- 10.3.2 Status and Control Register 2 (ADCSC2)
- 10.3.3 Data Result High Register (ADCRH)
- 10.3.4 Data Result Low Register (ADCRL)
- 10.3.5 Compare Value High Register (ADCCVH)
- 10.3.6 Compare Value Low Register (ADCCVL)
- 10.3.7 Configuration Register (ADCCFG)
- 10.3.8 Pin Control 1 Register (APCTL1)
- 10.3.9 Pin Control 2 Register (APCTL2)
- 10.3.10 Pin Control 3 Register (APCTL3)
- 10.4 Functional Description
- 10.5 Initialization Information
- 10.6 Application Information
- Chapter 11 Inter-Integrated Circuit (S08IICV2)
- Chapter 12 Serial Peripheral Interface (S08SPIV3)
- Chapter 13 Serial Communications Interface (S08SCIV4)
- Chapter 14 Real-Time Counter (S08RTCV1)
- Chapter 15 Timer Pulse-Width Modulator (S08TPMV3)
- Chapter 16 Development Support
- 16.1 Introduction
- 16.2 Background Debug Controller (BDC)
- 16.3 On-Chip Debug System (DBG)
- 16.4 Register Definition
- 16.4.1 BDC Registers and Control Bits
- 16.4.2 System Background Debug Force Reset Register (SBDFR)
- 16.4.3 DBG Registers and Control Bits
- 16.4.3.1 Debug Comparator A High Register (DBGCAH)
- 16.4.3.2 Debug Comparator A Low Register (DBGCAL)
- 16.4.3.3 Debug Comparator B High Register (DBGCBH)
- 16.4.3.4 Debug Comparator B Low Register (DBGCBL)
- 16.4.3.5 Debug FIFO High Register (DBGFH)
- 16.4.3.6 Debug FIFO Low Register (DBGFL)
- 16.4.3.7 Debug Control Register (DBGC)
- 16.4.3.8 Debug Trigger Register (DBGT)
- 16.4.3.9 Debug Status Register (DBGS)
- Appendix A Electrical Characteristics
- A.1 Introduction
- A.2 Parameter Classification
- A.3 Absolute Maximum Ratings
- A.4 Thermal Characteristics
- A.5 ESD Protection and Latch-Up Immunity
- A.6 DC Characteristics
- A.7 Supply Current Characteristics
- A.8 Analog Comparator (ACMP) Electricals
- A.9 ADC Characteristics
- A.10 External Oscillator (XOSC) Characteristics
- A.11 MCG Specifications
- A.12 AC Characteristics
- A.13 Flash and EEPROM
- A.14 EMC Performance
- Appendix B Timer Pulse-Width Modulator (TPMV2)
- Appendix C Ordering Information and Mechanical Drawings

Chapter 4 Memory
MC9S08DN60 Series Data Sheet, Rev 3
62 Freescale Semiconductor
4.5.11.6 Flash and EEPROM Command Register (FCMD)
Only six command codes are recognized in normal user modes, as shown in Table 4-15. All other
command codes are illegal and generate an access error. Refer to Section 4.5.3, “Program and Erase
Command Execution,” for a detailed discussion of Flash and EEPROM programming and erase
operations.
It is not necessary to perform a blank check command after a mass erase operation. Only blank check is
required as part of the security unlocking mechanism.
4
FACCERR
Access Error Flag — FACCERR is set automatically when the proper command sequence is not obeyed exactly
(the erroneous command is ignored), if a program or erase operation is attempted before the FCDIV register has
been initialized, or if the MCU enters stop while a command was in progress. For a more detailed discussion of
the exact actions that are considered access errors, see Section 4.5.6, “Access Errors.” FACCERR is cleared by
writing a 1 to FACCERR. Writing a 0 to FACCERR has no meaning or effect.
0 No access error.
1 An access error has occurred.
2
FBLANK
Verified as All Blank (erased) Flag — FBLANK is set automatically at the conclusion of a blank check command
if the entire Flash or EEPROM array was verified to be erased. FBLANK is cleared by clearing FCBEF to write a
new valid command. Writing to FBLANK has no meaning or effect.
0 After a blank check command is completed and FCCF = 1, FBLANK = 0 indicates the Flash or EEPROM array
is not completely erased.
1 After a blank check command is completed and FCCF = 1, FBLANK = 1 indicates the Flash or EEPROM array
is completely erased (all 0xFFFF).
76543210
R00000000
W FCMD
Reset 00000000
Figure 4-10. Flash and EEPROM Command Register (FCMD)
Table 4-15. Flash and EEPROM Commands
Command FCMD Equate File Label
Blank check 0x05 mBlank
Byte program 0x20 mByteProg
Burst program 0x25 mBurstProg
Sector erase 0x40 mSectorErase
Mass erase 0x41 mMassErase
Sector erase abort 0x47 mEraseAbort
Table 4-14. FSTAT Register Field Descriptions (continued)
Field Description