Datasheet
Table Of Contents
- Chapter 1 Device Overview
- Chapter 2 Pins and Connections
- Chapter 3 Modes of Operation
- Chapter 4 Memory
- 4.1 MC9S08DN60 Series Memory Map
- 4.2 Reset and Interrupt Vector Assignments
- 4.3 Register Addresses and Bit Assignments
- 4.4 RAM
- 4.5 Flash and EEPROM
- 4.5.1 Features
- 4.5.2 Program and Erase Times
- 4.5.3 Program and Erase Command Execution
- 4.5.4 Burst Program Execution
- 4.5.5 Sector Erase Abort
- 4.5.6 Access Errors
- 4.5.7 Block Protection
- 4.5.8 Vector Redirection
- 4.5.9 Security
- 4.5.10 EEPROM Mapping
- 4.5.11 Flash and EEPROM Registers and Control Bits
- 4.5.11.1 Flash and EEPROM Clock Divider Register (FCDIV)
- 4.5.11.2 Flash and EEPROM Options Register (FOPT and NVOPT)
- 4.5.11.3 Flash and EEPROM Configuration Register (FCNFG)
- 4.5.11.4 Flash and EEPROM Protection Register (FPROT and NVPROT)
- 4.5.11.5 Flash and EEPROM Status Register (FSTAT)
- 4.5.11.6 Flash and EEPROM Command Register (FCMD)
- Chapter 5 Resets, Interrupts, and General System Control
- 5.1 Introduction
- 5.2 Features
- 5.3 MCU Reset
- 5.4 Computer Operating Properly (COP) Watchdog
- 5.5 Interrupts
- 5.6 Low-Voltage Detect (LVD) System
- 5.7 MCLK Output
- 5.8 Reset, Interrupt, and System Control Registers and Control Bits
- 5.8.1 Interrupt Pin Request Status and Control Register (IRQSC)
- 5.8.2 System Reset Status Register (SRS)
- 5.8.3 System Background Debug Force Reset Register (SBDFR)
- 5.8.4 System Options Register 1 (SOPT1)
- 5.8.5 System Options Register 2 (SOPT2)
- 5.8.6 System Device Identification Register (SDIDH, SDIDL)
- 5.8.7 System Power Management Status and Control 1 Register (SPMSC1)
- 5.8.8 System Power Management Status and Control 2 Register (SPMSC2)
- Chapter 6 Parallel Input/Output Control
- 6.1 Port Data and Data Direction
- 6.2 Pull-up, Slew Rate, and Drive Strength
- 6.3 Pin Interrupts
- 6.4 Pin Behavior in Stop Modes
- 6.5 Parallel I/O and Pin Control Registers
- 6.5.1 Port A Registers
- 6.5.1.1 Port A Data Register (PTAD)
- 6.5.1.2 Port A Data Direction Register (PTADD)
- 6.5.1.3 Port A Pull Enable Register (PTAPE)
- 6.5.1.4 Port A Slew Rate Enable Register (PTASE)
- 6.5.1.5 Port A Drive Strength Selection Register (PTADS)
- 6.5.1.6 Port A Interrupt Status and Control Register (PTASC)
- 6.5.1.7 Port A Interrupt Pin Select Register (PTAPS)
- 6.5.1.8 Port A Interrupt Edge Select Register (PTAES)
- 6.5.2 Port B Registers
- 6.5.2.1 Port B Data Register (PTBD)
- 6.5.2.2 Port B Data Direction Register (PTBDD)
- 6.5.2.3 Port B Pull Enable Register (PTBPE)
- 6.5.2.4 Port B Slew Rate Enable Register (PTBSE)
- 6.5.2.5 Port B Drive Strength Selection Register (PTBDS)
- 6.5.2.6 Port B Interrupt Status and Control Register (PTBSC)
- 6.5.2.7 Port B Interrupt Pin Select Register (PTBPS)
- 6.5.2.8 Port B Interrupt Edge Select Register (PTBES)
- 6.5.3 Port C Registers
- 6.5.4 Port D Registers
- 6.5.4.1 Port D Data Register (PTDD)
- 6.5.4.2 Port D Data Direction Register (PTDDD)
- 6.5.4.3 Port D Pull Enable Register (PTDPE)
- 6.5.4.4 Port D Slew Rate Enable Register (PTDSE)
- 6.5.4.5 Port D Drive Strength Selection Register (PTDDS)
- 6.5.4.6 Port D Interrupt Status and Control Register (PTDSC)
- 6.5.4.7 Port D Interrupt Pin Select Register (PTDPS)
- 6.5.4.8 Port D Interrupt Edge Select Register (PTDES)
- 6.5.5 Port E Registers
- 6.5.6 Port F Registers
- 6.5.7 Port G Registers
- 6.5.1 Port A Registers
- Chapter 7 Central Processor Unit (S08CPUV3)
- 7.1 Introduction
- 7.2 Programmer’s Model and CPU Registers
- 7.3 Addressing Modes
- 7.4 Special Operations
- 7.5 HCS08 Instruction Set Summary
- Chapter 8 Multi-Purpose Clock Generator (S08MCGV1)
- 8.1 Introduction
- 8.2 External Signal Description
- 8.3 Register Definition
- 8.4 Functional Description
- 8.4.1 Operational Modes
- 8.4.1.1 FLL Engaged Internal (FEI)
- 8.4.1.2 FLL Engaged External (FEE)
- 8.4.1.3 FLL Bypassed Internal (FBI)
- 8.4.1.4 FLL Bypassed External (FBE)
- 8.4.1.5 PLL Engaged External (PEE)
- 8.4.1.6 PLL Bypassed External (PBE)
- 8.4.1.7 Bypassed Low Power Internal (BLPI)
- 8.4.1.8 Bypassed Low Power External (BLPE)
- 8.4.1.9 Stop
- 8.4.2 Mode Switching
- 8.4.3 Bus Frequency Divider
- 8.4.4 Low Power Bit Usage
- 8.4.5 Internal Reference Clock
- 8.4.6 External Reference Clock
- 8.4.7 Fixed Frequency Clock
- 8.4.1 Operational Modes
- 8.5 Initialization / Application Information
- 8.5.1 MCG Module Initialization Sequence
- 8.5.2 MCG Mode Switching
- 8.5.2.1 Example # 1: Moving from FEI to PEE Mode: External Crystal = 4 MHz, Bus Frequency = 8 MHz
- 8.5.2.2 Example # 2: Moving from PEE to BLPI Mode: External Crystal = 4 MHz, Bus Frequency =16 kHz
- 8.5.2.3 Example #3: Moving from BLPI to FEE Mode: External Crystal = 4 MHz, Bus Frequency = 16 MHz
- 8.5.2.4 Example # 4: Moving from FEI to PEE Mode: External Crystal = 8 MHz, Bus Frequency = 8 MHz
- 8.5.3 Calibrating the Internal Reference Clock (IRC)
- Chapter 9 Analog Comparator (S08ACMPV3)
- Chapter 10 Analog-to-Digital Converter (S08ADC12V1)
- 10.1 Introduction
- 10.2 External Signal Description
- 10.3 Register Definition
- 10.3.1 Status and Control Register 1 (ADCSC1)
- 10.3.2 Status and Control Register 2 (ADCSC2)
- 10.3.3 Data Result High Register (ADCRH)
- 10.3.4 Data Result Low Register (ADCRL)
- 10.3.5 Compare Value High Register (ADCCVH)
- 10.3.6 Compare Value Low Register (ADCCVL)
- 10.3.7 Configuration Register (ADCCFG)
- 10.3.8 Pin Control 1 Register (APCTL1)
- 10.3.9 Pin Control 2 Register (APCTL2)
- 10.3.10 Pin Control 3 Register (APCTL3)
- 10.4 Functional Description
- 10.5 Initialization Information
- 10.6 Application Information
- Chapter 11 Inter-Integrated Circuit (S08IICV2)
- Chapter 12 Serial Peripheral Interface (S08SPIV3)
- Chapter 13 Serial Communications Interface (S08SCIV4)
- Chapter 14 Real-Time Counter (S08RTCV1)
- Chapter 15 Timer Pulse-Width Modulator (S08TPMV3)
- Chapter 16 Development Support
- 16.1 Introduction
- 16.2 Background Debug Controller (BDC)
- 16.3 On-Chip Debug System (DBG)
- 16.4 Register Definition
- 16.4.1 BDC Registers and Control Bits
- 16.4.2 System Background Debug Force Reset Register (SBDFR)
- 16.4.3 DBG Registers and Control Bits
- 16.4.3.1 Debug Comparator A High Register (DBGCAH)
- 16.4.3.2 Debug Comparator A Low Register (DBGCAL)
- 16.4.3.3 Debug Comparator B High Register (DBGCBH)
- 16.4.3.4 Debug Comparator B Low Register (DBGCBL)
- 16.4.3.5 Debug FIFO High Register (DBGFH)
- 16.4.3.6 Debug FIFO Low Register (DBGFL)
- 16.4.3.7 Debug Control Register (DBGC)
- 16.4.3.8 Debug Trigger Register (DBGT)
- 16.4.3.9 Debug Status Register (DBGS)
- Appendix A Electrical Characteristics
- A.1 Introduction
- A.2 Parameter Classification
- A.3 Absolute Maximum Ratings
- A.4 Thermal Characteristics
- A.5 ESD Protection and Latch-Up Immunity
- A.6 DC Characteristics
- A.7 Supply Current Characteristics
- A.8 Analog Comparator (ACMP) Electricals
- A.9 ADC Characteristics
- A.10 External Oscillator (XOSC) Characteristics
- A.11 MCG Specifications
- A.12 AC Characteristics
- A.13 Flash and EEPROM
- A.14 EMC Performance
- Appendix B Timer Pulse-Width Modulator (TPMV2)
- Appendix C Ordering Information and Mechanical Drawings

Chapter 8 Multi-Purpose Clock Generator (S08MCGV1)
MC9S08DN60 Series Data Sheet, Rev 3
Freescale Semiconductor 147
— If entering FEE, set RDIV appropriately, clear the IREFS bit to switch to the external reference,
and leave the CLKS bits at %00 so that the output of the FLL is selected as the system clock
source.
— If entering FBE, clear the IREFS bit to switch to the external reference and change the CLKS
bits to %10 so that the external reference clock is selected as the system clock source. The
RDIV bits should also be set appropriately here according to the external reference frequency
because although the FLL is bypassed, it is still on in FBE mode.
— The internal reference can optionally be kept running by setting the IRCLKEN bit. This is
useful if the application will switch back and forth between internal and external modes. For
minimum power consumption, leave the internal reference disabled while in an external clock
mode.
3. After the proper configuration bits have been set, wait for the affected bits in the MCGSC register
to be changed appropriately, reflecting that the MCG has moved into the proper mode.
— If ERCLKEN was set in step 1 or the MCG is in FEE, FBE, PEE, PBE, or BLPE mode, and
EREFS was also set in step 1, wait here for the OSCINIT bit to become set indicating that the
external clock source has finished its initialization cycles and stabilized. Typical crystal startup
times are given in Appendix A, “Electrical Characteristics”.
— If in FEE mode, check to make sure the IREFST bit is cleared and the LOCK bit is set before
moving on.
— If in FBE mode, check to make sure the IREFST bit is cleared, the LOCK bit is set, and the
CLKST bits have changed to %10 indicating the external reference clock has been
appropriately selected. Although the FLL is bypassed in FBE mode, it is still on and will lock
in FBE mode.
To change from FEI clock mode to FBI clock mode, follow this procedure:
1. Change the CLKS bits to %01 so that the internal reference clock is selected as the system clock
source.
2. Wait for the CLKST bits in the MCGSC register to change to %01, indicating that the internal
reference clock has been appropriately selected.
8.5.2 MCG Mode Switching
When switching between operational modes of the MCG, certain configuration bits must be changed in
order to properly move from one mode to another. Each time any of these bits are changed (PLLS, IREFS,
CLKS, or EREFS), the corresponding bits in the MCGSC register (PLLST, IREFST, CLKST, or
OSCINIT) must be checked before moving on in the application software.
Additionally, care must be taken to ensure that the reference clock divider (RDIV) is set properly for the
mode being switched to. For instance, in PEE mode, if using a 4 MHz crystal, RDIV must be set to %001
(divide-by-2) or %010 (divide -by-4) in order to divide the external reference down to the required
frequency between 1 and 2 MHz.
The RDIV and IREFS bits should always be set properly before changing the PLLS bit so that the FLL or
PLL clock has an appropriate reference clock frequency to switch to.