Datasheet
Table Of Contents
- Chapter 1 Device Overview
- Chapter 2 Pins and Connections
- Chapter 3 Modes of Operation
- Chapter 4 Memory
- 4.1 MC9S08DN60 Series Memory Map
- 4.2 Reset and Interrupt Vector Assignments
- 4.3 Register Addresses and Bit Assignments
- 4.4 RAM
- 4.5 Flash and EEPROM
- 4.5.1 Features
- 4.5.2 Program and Erase Times
- 4.5.3 Program and Erase Command Execution
- 4.5.4 Burst Program Execution
- 4.5.5 Sector Erase Abort
- 4.5.6 Access Errors
- 4.5.7 Block Protection
- 4.5.8 Vector Redirection
- 4.5.9 Security
- 4.5.10 EEPROM Mapping
- 4.5.11 Flash and EEPROM Registers and Control Bits
- 4.5.11.1 Flash and EEPROM Clock Divider Register (FCDIV)
- 4.5.11.2 Flash and EEPROM Options Register (FOPT and NVOPT)
- 4.5.11.3 Flash and EEPROM Configuration Register (FCNFG)
- 4.5.11.4 Flash and EEPROM Protection Register (FPROT and NVPROT)
- 4.5.11.5 Flash and EEPROM Status Register (FSTAT)
- 4.5.11.6 Flash and EEPROM Command Register (FCMD)
- Chapter 5 Resets, Interrupts, and General System Control
- 5.1 Introduction
- 5.2 Features
- 5.3 MCU Reset
- 5.4 Computer Operating Properly (COP) Watchdog
- 5.5 Interrupts
- 5.6 Low-Voltage Detect (LVD) System
- 5.7 MCLK Output
- 5.8 Reset, Interrupt, and System Control Registers and Control Bits
- 5.8.1 Interrupt Pin Request Status and Control Register (IRQSC)
- 5.8.2 System Reset Status Register (SRS)
- 5.8.3 System Background Debug Force Reset Register (SBDFR)
- 5.8.4 System Options Register 1 (SOPT1)
- 5.8.5 System Options Register 2 (SOPT2)
- 5.8.6 System Device Identification Register (SDIDH, SDIDL)
- 5.8.7 System Power Management Status and Control 1 Register (SPMSC1)
- 5.8.8 System Power Management Status and Control 2 Register (SPMSC2)
- Chapter 6 Parallel Input/Output Control
- 6.1 Port Data and Data Direction
- 6.2 Pull-up, Slew Rate, and Drive Strength
- 6.3 Pin Interrupts
- 6.4 Pin Behavior in Stop Modes
- 6.5 Parallel I/O and Pin Control Registers
- 6.5.1 Port A Registers
- 6.5.1.1 Port A Data Register (PTAD)
- 6.5.1.2 Port A Data Direction Register (PTADD)
- 6.5.1.3 Port A Pull Enable Register (PTAPE)
- 6.5.1.4 Port A Slew Rate Enable Register (PTASE)
- 6.5.1.5 Port A Drive Strength Selection Register (PTADS)
- 6.5.1.6 Port A Interrupt Status and Control Register (PTASC)
- 6.5.1.7 Port A Interrupt Pin Select Register (PTAPS)
- 6.5.1.8 Port A Interrupt Edge Select Register (PTAES)
- 6.5.2 Port B Registers
- 6.5.2.1 Port B Data Register (PTBD)
- 6.5.2.2 Port B Data Direction Register (PTBDD)
- 6.5.2.3 Port B Pull Enable Register (PTBPE)
- 6.5.2.4 Port B Slew Rate Enable Register (PTBSE)
- 6.5.2.5 Port B Drive Strength Selection Register (PTBDS)
- 6.5.2.6 Port B Interrupt Status and Control Register (PTBSC)
- 6.5.2.7 Port B Interrupt Pin Select Register (PTBPS)
- 6.5.2.8 Port B Interrupt Edge Select Register (PTBES)
- 6.5.3 Port C Registers
- 6.5.4 Port D Registers
- 6.5.4.1 Port D Data Register (PTDD)
- 6.5.4.2 Port D Data Direction Register (PTDDD)
- 6.5.4.3 Port D Pull Enable Register (PTDPE)
- 6.5.4.4 Port D Slew Rate Enable Register (PTDSE)
- 6.5.4.5 Port D Drive Strength Selection Register (PTDDS)
- 6.5.4.6 Port D Interrupt Status and Control Register (PTDSC)
- 6.5.4.7 Port D Interrupt Pin Select Register (PTDPS)
- 6.5.4.8 Port D Interrupt Edge Select Register (PTDES)
- 6.5.5 Port E Registers
- 6.5.6 Port F Registers
- 6.5.7 Port G Registers
- 6.5.1 Port A Registers
- Chapter 7 Central Processor Unit (S08CPUV3)
- 7.1 Introduction
- 7.2 Programmer’s Model and CPU Registers
- 7.3 Addressing Modes
- 7.4 Special Operations
- 7.5 HCS08 Instruction Set Summary
- Chapter 8 Multi-Purpose Clock Generator (S08MCGV1)
- 8.1 Introduction
- 8.2 External Signal Description
- 8.3 Register Definition
- 8.4 Functional Description
- 8.4.1 Operational Modes
- 8.4.1.1 FLL Engaged Internal (FEI)
- 8.4.1.2 FLL Engaged External (FEE)
- 8.4.1.3 FLL Bypassed Internal (FBI)
- 8.4.1.4 FLL Bypassed External (FBE)
- 8.4.1.5 PLL Engaged External (PEE)
- 8.4.1.6 PLL Bypassed External (PBE)
- 8.4.1.7 Bypassed Low Power Internal (BLPI)
- 8.4.1.8 Bypassed Low Power External (BLPE)
- 8.4.1.9 Stop
- 8.4.2 Mode Switching
- 8.4.3 Bus Frequency Divider
- 8.4.4 Low Power Bit Usage
- 8.4.5 Internal Reference Clock
- 8.4.6 External Reference Clock
- 8.4.7 Fixed Frequency Clock
- 8.4.1 Operational Modes
- 8.5 Initialization / Application Information
- 8.5.1 MCG Module Initialization Sequence
- 8.5.2 MCG Mode Switching
- 8.5.2.1 Example # 1: Moving from FEI to PEE Mode: External Crystal = 4 MHz, Bus Frequency = 8 MHz
- 8.5.2.2 Example # 2: Moving from PEE to BLPI Mode: External Crystal = 4 MHz, Bus Frequency =16 kHz
- 8.5.2.3 Example #3: Moving from BLPI to FEE Mode: External Crystal = 4 MHz, Bus Frequency = 16 MHz
- 8.5.2.4 Example # 4: Moving from FEI to PEE Mode: External Crystal = 8 MHz, Bus Frequency = 8 MHz
- 8.5.3 Calibrating the Internal Reference Clock (IRC)
- Chapter 9 Analog Comparator (S08ACMPV3)
- Chapter 10 Analog-to-Digital Converter (S08ADC12V1)
- 10.1 Introduction
- 10.2 External Signal Description
- 10.3 Register Definition
- 10.3.1 Status and Control Register 1 (ADCSC1)
- 10.3.2 Status and Control Register 2 (ADCSC2)
- 10.3.3 Data Result High Register (ADCRH)
- 10.3.4 Data Result Low Register (ADCRL)
- 10.3.5 Compare Value High Register (ADCCVH)
- 10.3.6 Compare Value Low Register (ADCCVL)
- 10.3.7 Configuration Register (ADCCFG)
- 10.3.8 Pin Control 1 Register (APCTL1)
- 10.3.9 Pin Control 2 Register (APCTL2)
- 10.3.10 Pin Control 3 Register (APCTL3)
- 10.4 Functional Description
- 10.5 Initialization Information
- 10.6 Application Information
- Chapter 11 Inter-Integrated Circuit (S08IICV2)
- Chapter 12 Serial Peripheral Interface (S08SPIV3)
- Chapter 13 Serial Communications Interface (S08SCIV4)
- Chapter 14 Real-Time Counter (S08RTCV1)
- Chapter 15 Timer Pulse-Width Modulator (S08TPMV3)
- Chapter 16 Development Support
- 16.1 Introduction
- 16.2 Background Debug Controller (BDC)
- 16.3 On-Chip Debug System (DBG)
- 16.4 Register Definition
- 16.4.1 BDC Registers and Control Bits
- 16.4.2 System Background Debug Force Reset Register (SBDFR)
- 16.4.3 DBG Registers and Control Bits
- 16.4.3.1 Debug Comparator A High Register (DBGCAH)
- 16.4.3.2 Debug Comparator A Low Register (DBGCAL)
- 16.4.3.3 Debug Comparator B High Register (DBGCBH)
- 16.4.3.4 Debug Comparator B Low Register (DBGCBL)
- 16.4.3.5 Debug FIFO High Register (DBGFH)
- 16.4.3.6 Debug FIFO Low Register (DBGFL)
- 16.4.3.7 Debug Control Register (DBGC)
- 16.4.3.8 Debug Trigger Register (DBGT)
- 16.4.3.9 Debug Status Register (DBGS)
- Appendix A Electrical Characteristics
- A.1 Introduction
- A.2 Parameter Classification
- A.3 Absolute Maximum Ratings
- A.4 Thermal Characteristics
- A.5 ESD Protection and Latch-Up Immunity
- A.6 DC Characteristics
- A.7 Supply Current Characteristics
- A.8 Analog Comparator (ACMP) Electricals
- A.9 ADC Characteristics
- A.10 External Oscillator (XOSC) Characteristics
- A.11 MCG Specifications
- A.12 AC Characteristics
- A.13 Flash and EEPROM
- A.14 EMC Performance
- Appendix B Timer Pulse-Width Modulator (TPMV2)
- Appendix C Ordering Information and Mechanical Drawings

Chapter 8 Multi-Purpose Clock Generator (S08MCGV1)
MC9S08DN60 Series Data Sheet, Rev 3
Freescale Semiconductor 137
8.3.4 MCG Status and Control Register (MCGSC)
7 654 3 210
R LOLS LOCK PLLST IREFST CLKST OSCINIT
FTRIM
W
POR:
Reset:
0
0
0
0
0
0
1
1
0
0
0
0
0
0
0
U
Figure 8-6. MCG Status and Control Register (MCGSC)
Table 8-4. MCG Status and Control Register Field Descriptions
Field Description
7
LOLS
Loss of Lock Status — This bit is a sticky indication of lock status for the FLL or PLL. LOLS is set when lock
detection is enabled and after acquiring lock, the FLL or PLL output frequency has fallen outside the lock exit
frequency tolerance, D
unl
. LOLIE determines whether an interrupt request is made when set. LOLS is cleared by
reset or by writing a logic 1 to LOLS when LOLS is set. Writing a logic 0 to LOLS has no effect.
0 FLL or PLL has not lost lock since LOLS was last cleared.
1 FLL or PLL has lost lock since LOLS was last cleared.
6
LOCK
Lock Status — Indicates whether the FLL or PLL has acquired lock. Lock detection is disabled when both the
FLL and PLL are disabled. If the lock status bit is set then changing the value of any of the following bits IREFS,
PLLS, RDIV[2:0], TRIM[7:0] (if in FEI or FBI modes), or VDIV[3:0] (if in PBE or PEE modes), will cause the lock
status bit to clear and stay cleared until the FLL or PLL has reacquired lock. Stop mode entry will also cause the
lock status bit to clear and stay cleared until the FLL or PLL has reacquired lock. Entry into BLPI or BLPE mode
will also cause the lock status bit to clear and stay cleared until the MCG has exited these modes and the FLL
or PLL has reacquired lock.
0 FLL or PLL is currently unlocked.
1 FLL or PLL is currently locked.
5
PLLST
PLL Select Status — The PLLST bit indicates the current source for the PLLS clock. The PLLST bit does not
update immediately after a write to the PLLS bit due to internal synchronization between clock domains.
0 Source of PLLS clock is FLL clock.
1 Source of PLLS clock is PLL clock.
4
IREFST
Internal Reference Status — The IREFST bit indicates the current source for the reference clock. The IREFST
bit does not update immediately after a write to the IREFS bit due to internal synchronization between clock
domains.
0 Source of reference clock is external reference clock (oscillator or external clock source as determined by the
EREFS bit in the MCGC2 register).
1 Source of reference clock is internal reference clock.
3:2
CLKST
Clock Mode Status — The CLKST bits indicate the current clock mode. The CLKST bits do not update
immediately after a write to the CLKS bits due to internal synchronization between clock domains.
00 Encoding 0 — Output of FLL is selected.
01 Encoding 1 — Internal reference clock is selected.
10 Encoding 2 — External reference clock is selected.
11 Encoding 3 — Output of PLL is selected.