Datasheet
Table Of Contents
- Chapter 1 Device Overview
- Chapter 2 Pins and Connections
- Chapter 3 Modes of Operation
- Chapter 4 Memory
- 4.1 MC9S08DN60 Series Memory Map
- 4.2 Reset and Interrupt Vector Assignments
- 4.3 Register Addresses and Bit Assignments
- 4.4 RAM
- 4.5 Flash and EEPROM
- 4.5.1 Features
- 4.5.2 Program and Erase Times
- 4.5.3 Program and Erase Command Execution
- 4.5.4 Burst Program Execution
- 4.5.5 Sector Erase Abort
- 4.5.6 Access Errors
- 4.5.7 Block Protection
- 4.5.8 Vector Redirection
- 4.5.9 Security
- 4.5.10 EEPROM Mapping
- 4.5.11 Flash and EEPROM Registers and Control Bits
- 4.5.11.1 Flash and EEPROM Clock Divider Register (FCDIV)
- 4.5.11.2 Flash and EEPROM Options Register (FOPT and NVOPT)
- 4.5.11.3 Flash and EEPROM Configuration Register (FCNFG)
- 4.5.11.4 Flash and EEPROM Protection Register (FPROT and NVPROT)
- 4.5.11.5 Flash and EEPROM Status Register (FSTAT)
- 4.5.11.6 Flash and EEPROM Command Register (FCMD)
- Chapter 5 Resets, Interrupts, and General System Control
- 5.1 Introduction
- 5.2 Features
- 5.3 MCU Reset
- 5.4 Computer Operating Properly (COP) Watchdog
- 5.5 Interrupts
- 5.6 Low-Voltage Detect (LVD) System
- 5.7 MCLK Output
- 5.8 Reset, Interrupt, and System Control Registers and Control Bits
- 5.8.1 Interrupt Pin Request Status and Control Register (IRQSC)
- 5.8.2 System Reset Status Register (SRS)
- 5.8.3 System Background Debug Force Reset Register (SBDFR)
- 5.8.4 System Options Register 1 (SOPT1)
- 5.8.5 System Options Register 2 (SOPT2)
- 5.8.6 System Device Identification Register (SDIDH, SDIDL)
- 5.8.7 System Power Management Status and Control 1 Register (SPMSC1)
- 5.8.8 System Power Management Status and Control 2 Register (SPMSC2)
- Chapter 6 Parallel Input/Output Control
- 6.1 Port Data and Data Direction
- 6.2 Pull-up, Slew Rate, and Drive Strength
- 6.3 Pin Interrupts
- 6.4 Pin Behavior in Stop Modes
- 6.5 Parallel I/O and Pin Control Registers
- 6.5.1 Port A Registers
- 6.5.1.1 Port A Data Register (PTAD)
- 6.5.1.2 Port A Data Direction Register (PTADD)
- 6.5.1.3 Port A Pull Enable Register (PTAPE)
- 6.5.1.4 Port A Slew Rate Enable Register (PTASE)
- 6.5.1.5 Port A Drive Strength Selection Register (PTADS)
- 6.5.1.6 Port A Interrupt Status and Control Register (PTASC)
- 6.5.1.7 Port A Interrupt Pin Select Register (PTAPS)
- 6.5.1.8 Port A Interrupt Edge Select Register (PTAES)
- 6.5.2 Port B Registers
- 6.5.2.1 Port B Data Register (PTBD)
- 6.5.2.2 Port B Data Direction Register (PTBDD)
- 6.5.2.3 Port B Pull Enable Register (PTBPE)
- 6.5.2.4 Port B Slew Rate Enable Register (PTBSE)
- 6.5.2.5 Port B Drive Strength Selection Register (PTBDS)
- 6.5.2.6 Port B Interrupt Status and Control Register (PTBSC)
- 6.5.2.7 Port B Interrupt Pin Select Register (PTBPS)
- 6.5.2.8 Port B Interrupt Edge Select Register (PTBES)
- 6.5.3 Port C Registers
- 6.5.4 Port D Registers
- 6.5.4.1 Port D Data Register (PTDD)
- 6.5.4.2 Port D Data Direction Register (PTDDD)
- 6.5.4.3 Port D Pull Enable Register (PTDPE)
- 6.5.4.4 Port D Slew Rate Enable Register (PTDSE)
- 6.5.4.5 Port D Drive Strength Selection Register (PTDDS)
- 6.5.4.6 Port D Interrupt Status and Control Register (PTDSC)
- 6.5.4.7 Port D Interrupt Pin Select Register (PTDPS)
- 6.5.4.8 Port D Interrupt Edge Select Register (PTDES)
- 6.5.5 Port E Registers
- 6.5.6 Port F Registers
- 6.5.7 Port G Registers
- 6.5.1 Port A Registers
- Chapter 7 Central Processor Unit (S08CPUV3)
- 7.1 Introduction
- 7.2 Programmer’s Model and CPU Registers
- 7.3 Addressing Modes
- 7.4 Special Operations
- 7.5 HCS08 Instruction Set Summary
- Chapter 8 Multi-Purpose Clock Generator (S08MCGV1)
- 8.1 Introduction
- 8.2 External Signal Description
- 8.3 Register Definition
- 8.4 Functional Description
- 8.4.1 Operational Modes
- 8.4.1.1 FLL Engaged Internal (FEI)
- 8.4.1.2 FLL Engaged External (FEE)
- 8.4.1.3 FLL Bypassed Internal (FBI)
- 8.4.1.4 FLL Bypassed External (FBE)
- 8.4.1.5 PLL Engaged External (PEE)
- 8.4.1.6 PLL Bypassed External (PBE)
- 8.4.1.7 Bypassed Low Power Internal (BLPI)
- 8.4.1.8 Bypassed Low Power External (BLPE)
- 8.4.1.9 Stop
- 8.4.2 Mode Switching
- 8.4.3 Bus Frequency Divider
- 8.4.4 Low Power Bit Usage
- 8.4.5 Internal Reference Clock
- 8.4.6 External Reference Clock
- 8.4.7 Fixed Frequency Clock
- 8.4.1 Operational Modes
- 8.5 Initialization / Application Information
- 8.5.1 MCG Module Initialization Sequence
- 8.5.2 MCG Mode Switching
- 8.5.2.1 Example # 1: Moving from FEI to PEE Mode: External Crystal = 4 MHz, Bus Frequency = 8 MHz
- 8.5.2.2 Example # 2: Moving from PEE to BLPI Mode: External Crystal = 4 MHz, Bus Frequency =16 kHz
- 8.5.2.3 Example #3: Moving from BLPI to FEE Mode: External Crystal = 4 MHz, Bus Frequency = 16 MHz
- 8.5.2.4 Example # 4: Moving from FEI to PEE Mode: External Crystal = 8 MHz, Bus Frequency = 8 MHz
- 8.5.3 Calibrating the Internal Reference Clock (IRC)
- Chapter 9 Analog Comparator (S08ACMPV3)
- Chapter 10 Analog-to-Digital Converter (S08ADC12V1)
- 10.1 Introduction
- 10.2 External Signal Description
- 10.3 Register Definition
- 10.3.1 Status and Control Register 1 (ADCSC1)
- 10.3.2 Status and Control Register 2 (ADCSC2)
- 10.3.3 Data Result High Register (ADCRH)
- 10.3.4 Data Result Low Register (ADCRL)
- 10.3.5 Compare Value High Register (ADCCVH)
- 10.3.6 Compare Value Low Register (ADCCVL)
- 10.3.7 Configuration Register (ADCCFG)
- 10.3.8 Pin Control 1 Register (APCTL1)
- 10.3.9 Pin Control 2 Register (APCTL2)
- 10.3.10 Pin Control 3 Register (APCTL3)
- 10.4 Functional Description
- 10.5 Initialization Information
- 10.6 Application Information
- Chapter 11 Inter-Integrated Circuit (S08IICV2)
- Chapter 12 Serial Peripheral Interface (S08SPIV3)
- Chapter 13 Serial Communications Interface (S08SCIV4)
- Chapter 14 Real-Time Counter (S08RTCV1)
- Chapter 15 Timer Pulse-Width Modulator (S08TPMV3)
- Chapter 16 Development Support
- 16.1 Introduction
- 16.2 Background Debug Controller (BDC)
- 16.3 On-Chip Debug System (DBG)
- 16.4 Register Definition
- 16.4.1 BDC Registers and Control Bits
- 16.4.2 System Background Debug Force Reset Register (SBDFR)
- 16.4.3 DBG Registers and Control Bits
- 16.4.3.1 Debug Comparator A High Register (DBGCAH)
- 16.4.3.2 Debug Comparator A Low Register (DBGCAL)
- 16.4.3.3 Debug Comparator B High Register (DBGCBH)
- 16.4.3.4 Debug Comparator B Low Register (DBGCBL)
- 16.4.3.5 Debug FIFO High Register (DBGFH)
- 16.4.3.6 Debug FIFO Low Register (DBGFL)
- 16.4.3.7 Debug Control Register (DBGC)
- 16.4.3.8 Debug Trigger Register (DBGT)
- 16.4.3.9 Debug Status Register (DBGS)
- Appendix A Electrical Characteristics
- A.1 Introduction
- A.2 Parameter Classification
- A.3 Absolute Maximum Ratings
- A.4 Thermal Characteristics
- A.5 ESD Protection and Latch-Up Immunity
- A.6 DC Characteristics
- A.7 Supply Current Characteristics
- A.8 Analog Comparator (ACMP) Electricals
- A.9 ADC Characteristics
- A.10 External Oscillator (XOSC) Characteristics
- A.11 MCG Specifications
- A.12 AC Characteristics
- A.13 Flash and EEPROM
- A.14 EMC Performance
- Appendix B Timer Pulse-Width Modulator (TPMV2)
- Appendix C Ordering Information and Mechanical Drawings

Chapter 7 Central Processor Unit (S08CPUV3)
MC9S08DN60 Series Data Sheet, Rev 3
Freescale Semiconductor 113
7.3 Addressing Modes
Addressing modes define the way the CPU accesses operands and data. In the HCS08, all memory, status
and control registers, and input/output (I/O) ports share a single 64-Kbyte linear address space so a 16-bit
binary address can uniquely identify any memory location. This arrangement means that the same
instructions that access variables in RAM can also be used to access I/O and control registers or nonvolatile
program space.
Some instructions use more than one addressing mode. For instance, move instructions use one addressing
mode to specify the source operand and a second addressing mode to specify the destination address.
Instructions such as BRCLR, BRSET, CBEQ, and DBNZ use one addressing mode to specify the location
of an operand for a test and then use relative addressing mode to specify the branch destination address
when the tested condition is true. For BRCLR, BRSET, CBEQ, and DBNZ, the addressing mode listed in
the instruction set tables is the addressing mode needed to access the operand to be tested, and relative
addressing mode is implied for the branch destination.
7.3.1 Inherent Addressing Mode (INH)
In this addressing mode, operands needed to complete the instruction (if any) are located within CPU
registers so the CPU does not need to access memory to get any operands.
7.3.2 Relative Addressing Mode (REL)
Relative addressing mode is used to specify the destination location for branch instructions. A signed 8-bit
offset value is located in the memory location immediately following the opcode. During execution, if the
branch condition is true, the signed offset is sign-extended to a 16-bit value and is added to the current
contents of the program counter, which causes program execution to continue at the branch destination
address.
7.3.3 Immediate Addressing Mode (IMM)
In immediate addressing mode, the operand needed to complete the instruction is included in the object
code immediately following the instruction opcode in memory. In the case of a 16-bit immediate operand,
the high-order byte is located in the next memory location after the opcode, and the low-order byte is
located in the next memory location after that.
7.3.4 Direct Addressing Mode (DIR)
In direct addressing mode, the instruction includes the low-order eight bits of an address in the direct page
(0x0000–0x00FF). During execution a 16-bit address is formed by concatenating an implied 0x00 for the
high-order half of the address and the direct address from the instruction to get the 16-bit address where
the desired operand is located. This is faster and more memory efficient than specifying a complete 16-bit
address for the operand.