Datasheet
Monitor ROM (MON)
MC68HC908LJ12 — Rev. 2.1 Technical Data
Freescale Semiconductor Monitor ROM (MON) 173
10.6.1 PRGRNGE
PRGRNGE is used to program a range of FLASH locations with data 
loaded into the data array.
The start location of the FLASH to be programmed is specified by the 
address ADDRH:ADDRL and the number of bytes from this location is 
specified by DATASIZE. The maximum number of bytes that can be 
programmed in one routine call is 255 bytes (max. DATASIZE is 255).
ADDRH:ADDRL do not need to be at a page boundary, the routine 
handles any boundary misalignment during programming. A check to 
see that all bytes in the specified range are erased is not performed by 
this routine prior programming. Nor does this routine do a verification 
after programming, so there is no return confirmation that programming 
was successful. User must assure that the range specified is first 
erased.
The coding example below is to program 64 bytes of data starting at 
FLASH location $EF00, with a bus speed of 4.9152 MHz. The coding 
assumes the data block is already loaded in RAM, with the address 
pointer, FILE_PTR, pointing to the first byte of the data block.
Table 10-11. PRGRNGE Routine
Routine Name PRGRNGE
Routine Description Program a range of locations
Calling Address $FC06
Stack Used 14 bytes
Data Block Format Bus speed (BUS_SPD)
Data size (DATASIZE)
Start address high (ADDRH)
Start address (ADDRL)
Data 1 (DATA1)
:
Data N (DATAN)