Datasheet

BGA7127 All information provided in this document is subject to legal disclaimers. © NXP B.V. 2010. All rights reserved.
Product data sheet Rev. 3 — 3 December 2010 4 of 25
NXP Semiconductors
BGA7127
400 MHz to 2700 MHz 0.5 W high linearity silicon amplifier
6. Limiting values
[1] See Figure 3 for safe operating area.
[2] The supply current is adjustable. See Section 8.1 “
Supply current adjustment and Section 12 “Application information.
[3] If V
ctrl(sd)
exceeds V
CC(BIAS)
, the internal ESD circuit can be damaged.
The recommended preventive measure is to limit the I
ctrl(sd)
to 20 mA.
If the SHDN function is not used, the SHDN
pin should be connected to V
CC(BIAS)
.
[4] Withstands switching between zero and maximum P
i(RF)
.
Table 5. Limiting values
In accordance with the Absolute Maximum Rating System (IEC 60134).
Symbol Parameter Conditions Min Max Unit
V
CC(RF)
RF supply voltage
[1]
-6.0V
V
CC(BIAS)
bias supply voltage
[1]
-6.0V
I
CC
supply current
[1][2]
-325mA
V
ctrl(sd)
shutdown control voltage
[3]
0.0 V
CC(BIAS)
V
P
i(RF)
RF input power f = 2140 MHz; switched
[4]
-25dBm
T
case
case temperature 40 +85 °C
T
j
junction temperature - 150 °C
V
ESD
electrostatic discharge voltage Human Body Model (HBM);
According JEDEC standard 22-A114E
-2000V
Charged Device Model (CDM);
According JEDEC standard 22-C101B
-500V
Exceeding the safe operating area limits may cause serious damage to the product.
The impact on I
CC
due to the spread of the external ICQ resistor (R2) should be taken into account.
The product-spread on I
CC
should be taken into account (See Section 8 “Static characteristics).
Fig 3. BGA7127 DC safe operating area
V
CC(RF)
(V)
276453
001aal536
200
250
150
300
350
I
CC
(mA)
100