Datasheet
74LV4053 All information provided in this document is subject to legal disclaimers. © NXP Semiconductors N.V. 2014. All rights reserved.
Product data sheet Rev. 5 — 18 September 2014 12 of 27
NXP Semiconductors
74LV4053
Triple single-pole double-throw analog switch
[1] All typical values are measured at T
amb
=25C.
[2] t
pd
is the same as t
PLH
and t
PHL
.
t
en
is the same as t
PZL
and t
PZH
.
t
dis
is the same as t
PLZ
and t
PHZ
.
[3] Typical values are measured at nominal supply voltage (V
CC
= 3.3 V).
[4] C
PD
is used to determine the dynamic power dissipation (P
D
in W).
P
D
=C
PD
V
CC
2
f
i
N+((C
L
+ C
SW
) V
CC
2
f
o
) where:
f
i
= input frequency in MHz, f
o
= output frequency in MHz
C
L
= output load capacitance in pF
C
SW
= maximum switch capacitance in pF;
V
CC
= supply voltage in Volts
N = number of inputs switching
(C
L
V
CC
2
f
o
) = sum of the outputs.
t
dis
disable time E to nYn, nZ; see Figure 14
[2]
V
CC
=1.2V - 95 - - - ns
V
CC
=2.0V - 34 61 - 73 ns
V
CC
=2.7V - 26 46 - 54 ns
V
CC
= 3.0 V to 3.6 V; C
L
=15pF
[3]
-17- - -ns
V
CC
= 3.0 V to 3.6 V
[3]
-2037 - 44ns
V
CC
=4.5V - 18 32 - 38 ns
V
CC
=6.0V - 15 25 - 30 ns
Sn to nYn, nZ; see Figure 14
[2]
V
CC
=1.2V - 90 - - - ns
V
CC
=2.0V - 32 59 - 70 ns
V
CC
=2.7V - 24 44 - 52 ns
V
CC
= 3.0 V to 3.6 V; C
L
=15pF
[3]
-16- - -ns
V
CC
= 3.0 V to 3.6 V
[3]
-1936 - 42ns
V
CC
=4.5V - 17 31 - 36 ns
V
CC
=6.0V - 14 24 - 28 ns
C
PD
power dissipation
capacitance
C
L
=50pF; f
i
= 1 MHz;
V
I
=GNDtoV
CC
[4]
-36- - -pF
Table 8. Dynamic characteristics
…continued
Voltages are referenced to GND (ground = 0 V). For test circuit see Figure 15.
Symbol Parameter Conditions 40 C to +85 C 40 C to +125 C Unit
Min Typ
[1]
Max Min Max