Datasheet
Table Of Contents
- 1. General description
- 2. Features and benefits
- 3. Applications
- 4. Ordering information
- 5. Functional diagram
- 6. Pinning information
- 7. Functional description
- 8. Limiting values
- 9. Recommended operating conditions
- 10. Static characteristics
- 11. Dynamic characteristics
- 12. Waveforms
- 13. Package outline
- 14. Abbreviations
- 15. Revision history
- 16. Legal information
- 17. Contact information
- 18. Contents

74HC4024 All information provided in this document is subject to legal disclaimers. © NXP B.V. 2013. All rights reserved.
Product data sheet Rev. 7 — 31 October 2013 11 of 19
NXP Semiconductors
74HC4024
7-stage binary ripple counter
Test data is given in Table 8.
Definitions for test circuit:
R
T
= Termination resistance should be equal to output impedance Z
o
of the pulse generator.
C
L
= Load capacitance including jig and probe capacitance.
Fig 7. Test circuit for measuring switching times
mna101
V
CC
V
I
V
O
R
T
C
L
PULSE
GENERATOR
DUT
Table 8. Test data
Supply Input Load
V
CC
V
I
t
r
, t
f
C
L
2.0 V V
CC
6 ns 50 pF
4.5 V V
CC
6 ns 50 pF
6.0 V V
CC
6 ns 50 pF
5.0 V V
CC
6 ns 15 pF