Lead batteries
From the program select screen, use the STOP or - key to select Acid Lead (Pb) battery type and
then press the START key.
PROGRAM SELECT
Pb BATT
Pb CHARGE
5.0A 6.0V(3p)
By pressing the + and - keys, you can select the different function modes:
Pb CHARGE Normal charge
Pb DISCHARGE Discharge the battery
Modifying the settings
If you need to modify the charge or discharge settings, press the START key so that the charge/
discharge current or battery voltage (cell count) setting blinks.
Use the + and - keys to increase or decrease the charge or discharge current or the cell count (2V
to 20V – 1P to 10P).
Launching the charge or discharge
Once you are ready to start the charge or discharge, press and hold the START key for three seconds.
Number of cells Charge current Battery voltage
Pb-3 5.0A 6.00V
CHG 000:40 00010
Mode Charge time Charged capacity
CHG = normal charge mode
DSC = discharge mode