Specifications

www.nvisionweb.net 13
Once the charger has determined that the charge or discharge is complete, the charger stops and the
“FULL” or “END” message is displayed.
FULL 5.0A 8.40V
CHG 030:00 03000
Note: you can stop the current process at any time by pressing the STOP key.
NiCd/NiMH batteries
From the program select screen, use the STOP or - key to select NiCd or NiMH battery type and then
press the START key.
PROGRAM SELECT
NiMH BATT
NiMH CHARGE Man
CURRENT 5.0A
By pressing the + and - keys, you can select the different function modes:
NiMH CHARGE Man Normal charge
NiMH CHARGE Aut Normal charge, auto charge current up to the user limit
NiMH DISCHARGE Discharge the battery
NiMH CYCLE Cycle the battery
Modifying the settings
To modify the charge settings, press the START key so that the charge current blinks. Use the +
and - keys to increase or decrease the charge current.
NiMH CHARGE Man
CURRENT 5.0A