Specifications

www.nvisionweb.net 11
Battery charging
The charger has default settings which are compatible with the most popular batteries. If you wish to
change the default settings please go to p.13 of these instructions.
Lithium batteries (LiPo, LiFe and Li-Ion)
From the program select screen, use the STOP or - keys to select LiPo battery type and then press
the START key.
PROGRAM SELECT
LiPo Battery
LiPo CHARGE 3S
C= 2500mAh 6.0A
By pressing the + and - keys, you can select the different function modes:
LiPo CHARGE Normal charge, balancing if balance connector connected
(not mandatory but recommended)
LiPo BAL-CHG Balance charge, use of balancing connector mandatory
LiPo STORAGE Storage charge or discharge (to 50% of capacity)
LiPo DCHG Discharge of the battery
Warning! For increased safety, we recommend that you always connect the battery‘s balancing
connector to the charger when charging LiPo or LiFe batteries.
Modifying the settings
Press the START key so that the charge/discharge current or battery voltage (cell count) setting blinks.
Use the + and - keys to adjust the cell count (1S to 6S), conrm with ENTER and use the + and - key
to adjust the max. capacity. After conrmation with ENTER set the charge or discharge current.