4.1.2 Power Supplies
The Tegra 250 has 29 power rails (3 cores, 14 analog and 12 digital I/O). Depending on system design, many of the rails can
share a power supply, and some are not needed for all designs. The example shown in Table 4 is based on the Smartbook
Development System design and should be representative of these types of designs. This table mainly lists the supplies
required by the Tegra 250. Others are required to support some of the peripherals typically seen in a Smartbook.
Table 4 Tegra 250 Power Supply Allocation Example
Power Rails
Supported
Voltages (V)
Voltage (V)
(Tegra 200
Series DB)
Power Supply Enable
VDD_RTC 1.0 – 1.2 Up to 1.2 PMU LDO2 PMU SM2 (3.7V) + Internal Trigger
VDD_CORE 1.0 – 1.2 Up to 1.2 PMU SM0 CORE_PWR_REQ + Internal Trigger
VDD_CPU 0.9 – 1.0 Up to 1.0 PMU SM0 CPU_PWR_REQ + Internal Trigger
AVDD_PLLx 1.1 1.1 PMU LDO1 PMU SM2 (3.7V) + Internal Trigger
VDDIO_SYS, AVDD_OSC 1.8 1.8 PMU LD04 PMU SM2 (3.7V) + Internal Trigger
VDDIO_LCD,VDDIO_BB,VDDIO_AUDIO,VDDIO_UART
VDDIO_DDR
1.8,2.8,3.3
1.8
1.8 TPS51116, DC/DC
EN_VDD_1V8
(PG_VDDIO_SYS – PMU LDO4PG)
AVDD_USB, AVDD_USB_PLL 3.3 3.3 PMU LDO3 PMU SM2 (3.7V) + Internal Trigger
VDD_DDR_RX 2.8 2.8 PMU LDO9 PMU SM2 (3.7V) + Internal Trigger
VDDIO_NAND (if 3.3V), VDDIO_SDIO, VDDIO_VI 1.8,2.8,3.3 3.3 TPS51220, DC/DC EN_VDD_3V3 (Output of SR)
AVDD_VDAC 2.7 – 3.3 2.85 PMU LDO6 PMU SM2 (3.7V)
AVDD_HDMI 3.3 3.3 PMU LDO7 PMU SM2 (3.7V)
AVDD_HDMI_PLL 1.8, 2.5 1.8 PMU LDO8 PMU SM2 (3.7V)
VDDIO_PEX_CLK 3.3 3.3 PMU LDO0 PMU SM2 (3.7V)
AVDD_DSI_CSI 1.2 1.2 TPS72012, LDO2 EN_VDD_1V2 (PMU GPIO)
AVDD_PCIE, AVDD_PEX, AVDD_PEX_PLL, VDD_PEX 1.05 1.05 TPS62290, DC/DC EN_VDD_1V05 (PMU GPIO)
VCORE_MMC 2.7 – 3.6 2.85 PMU LD05
Note:
1: This includes pins AVDD_PLLA_C_P (powers PLLA, PLLC and PLLP), AVDD_PLLM, AVDD_PLLU (powers
PLLU and PLLD) and AVDD_PLLX. If PCIE not supported in a design, AVDD_PCIE should be left
unpowered as the leakage is significant.
2: Supplies must meet maximum rate requirement in AP20 EMT of 165mV/us