Datasheet
3.11.17
19” compatible AC/DC switched mode
09/2001
Technical data
Input parameters
Mains-
voltage
Nominal
values V
AC
100 – 240 V
AC
Operating-
ranges
90 – 254 V
AC
100 – 360 V
DC
Mains nominal current at
90 V
AC
1.4 A
Mains frequency range 50 – 60 Hz
Power factor correction in
accordance with
EN 61000-3-2
Efficiency type > 73 %
Switch-on current I
P
(with 230 V
AC
)
<15A
Output parameters at 190/90 V
AC
Output power max. (50°C)
[W]
40/35 60/38.4
Output
voltage
[V]
V
1
V
2
,V
3
factory set 5 V ± 12 V ± 15 V
Adjustment-
range V
4.95– 5.5 11.5–
15.7
11.5–
15.7
Output cur-
rent [A]
0 ... 50°C 8 /7 2.5/1.6 2/1.3
70°C 6/5.5 1.5/1.2 1.2/1
Current limitation shuts
the output off after approx.
20 ms, automatically
resets after approx. 0.5 s
Permanently short-circuit
protected
Residual ripple/
interferencevoltage
(BW: 30 MHz) [mV
PP
]
< 80 < 150
Mains and load control,
static (load change
0–100%) [mV
PP
]
< 25 < 120
Temperature coefficient -0.015 %/K
Dynamic control deviations
(load change: 10 ... 100 % with 100 Hz; dl/dt = 0.25 A/µs)
Control time at
0.01 V
1 Nominal
[ms]
<0.8
Overshoot and undershoot
amplitude [mV]
< 250
Protection and monitoring facilities
Switch-on time < 1.5 s
Mains fuse, high breaking
sluggish
4 A/250 V
AC
, 5 20 mm,
DIN EN 60127-2/V
Power failurebridging at
V
AC
=90V
AC
and 100 %
load V
1
/V
2,3
>16ms/5ms
Over-voltage protection
OVP (shuts power supply
off, diode alloyed through)
set to
<7.2V –
Remote sense
compensated
Max. 0.5 V
"Output voltage ok"
signalling
"Output OK" signal, active high
Test and environmental conditions
Climatic test to IEC 68-2-38
Shock and vibration test in
accordance with accelera-
tion of 2 g
EN 60068-2-6
Height 3 U/depth 160 mm Width 8 HP
Weight (mass) 0.55 kg
CE Interference
emission
EN 50081-1,
EN 55011 Class B,
interference-
immunity,
degree of
severity 3
EN 50082-2,
EN 61000-4-2, EN 61000-4-3,
EN 61000-4-4, EN 61000-4-5,
EN 61000-4-6,
Safety,
class of
protection 1
EN 60950
High voltage
test to
EN 60950
Input-output 4.3 kV
DC
Input PE 2.2 kV
DC
Output PE 0.7 kV
DC
UL 1950 applied for
Power supply
maintenance-free
Ye s
Cooling Convection
Operation/storage ambient
temperature
0 ... 70°C / -20 ... +85°C
MTBF at full load,
T
U
=40°C
220,000 h
Schematic wiring diagram
DIJM0026