Datasheet

3.11.7
19” compatible AC/DC switched mode
09/2001
Technical data
Input parameters
Mains-
voltage
Nominal
values V
AC
100 240 V
AC
Operating-
ranges
90 254 V
AC
100 360 V
DC
Mains nominal current
at 90 V
AC
1.6 A
Mains frequency range 50 60 Hz
Power factor correction
in accordance with
EN 61000-3-2
Efficiency type 63 % 75 % 77 %
Switch-on current I
P
(with 230 V
AC
)
<20A
Output parameters at 190/90 V
AC
Output power max.
(50 °C) [W]
80/65 100/72 100/
80
Output
voltage
[V]
factory set 5 12 15 24
Adjustment
range V
4.95
5.5
11.515.7 21.8
25.3
Output
current [A]
0 ... 50°C 16/13 8.3/6 6.6/
4.8
4.2/
3.2
70°C 12/
10.5
6/4.8 4.8/
3.8
3.2/
2.6
Current limitation shuts
the output off after
approx. 10 ms, auto-
matically resets after
approx. 2 s, shuts
power supply off
following longer
overload.
Permanently short-circuit protected
Residual ripple/
Interference voltage
(BW: 30 MHz) [mV
PP
]
< 50 < 50 < 60
Mains and load control,
static (load change 0
100 %) [mV
PP
]
< 20 < 80 < 100 < 80
Temperature
coefficient
-0.015 %/K
CSB and output decou-
pled via diode
mounted
Dynamic control deviations
(load change: 10 ... 100 % with 100 Hz; dl/dt = 0.25 A/µs)
Control time at
0.01 V
1 Nominal
[ms]
<0.8 <0.2 <0.1
Overshoot and
undershoot amplitude
< 300 mV
Protection and monitoring facilities
Switch-on time < 0.8 s
Mains fuse 4 A/250 V
AC
, 5 20 mm,
EN 60127-2/V
Power failurebridging at
V
AC
=90V
AC
and 100 %
load
>14
ms
>14
ms
>10
ms
>16
ms
Over-voltage protection
OVP limits UA to
<8.2 V <19 V <34 V
Remote sense
compensated
Max. 0.5 V
"Output voltage ok"
signalling
"Output OK" signal, active high
High level [V] 5 12 15 20
Time delay 100 250 ms
Test and environmental conditions
Climatic test to IEC 68-2-38
Shock and vibration test
in accordance with
acceleration of 2 g
EN 60068-2-6
Height 3 U/
depth 160 mm
Width 6 HP
Weight (mass) 0.55 kg
CE Interference
emission
EN 50081-1,
EN 55011 Class B,
Interference
immunity,
degree of
severity 3
EN 50082-2
EN 61000-4-2, EN 61000-4-3,
EN 61000-4-4, EN 61000-4-5,
EN 61000-4-6, EN 61000-4-11
Safety,
class of
protection 1
EN 60950
High
voltage
test to
EN 60950
Input-output 4.3 kV
DC
Input PE 2.2 kV
DC
Output PE 0.7 kV
DC
UL 1950 applied for
Power supply
maintenance-free
Ye s
Cooling Convection
Operation/storage
ambient temperature
0 ... 70°C / -20 ... +85°C
MTBF at full load,
T
U
=40°C
280,000 h (5 V 220,000 h)
Schematic wiring diagram
DIJM0032