Instruction Manual
nVent.com/RAYCHEM | 3
7 8
6B
• Pull exposed braid back over metal clip.
• Apply a small amout of lubricant to the jacket surface
near the end of the cable.
• Avoid using large amounts of lubricant on the exposed
end of the cable.
• Insert prepared heating cable
end into connector. Push until
heating cable is fully inserted and end is
visible through opening in connection cover
plate.
Note: RayClic connection kits are designed to be installed only
once; the heating cable cannot be removed once installed
IceStop and XL-Trace Edge Only
6A
• Using wire cutters, cut away 1 inch of the braid.
• Pull exposed braid back over metal clip.
• Using wire cutters, cut away aluminum wrap.
HWAT Only