Instruction Manual

nVent.com/RAYCHEM | 3
7 8
6B
Pull exposed braid back over metal clip.
Apply a small amout of lubricant to the jacket surface
near the end of the cable.
Avoid using large amounts of lubricant on the exposed
end of the cable.
Insert prepared heating cable
end into connector. Push until
heating cable is fully inserted and end is
visible through opening in connection cover
plate.
Note: RayClic connection kits are designed to be installed only
once; the heating cable cannot be removed once installed
IceStop and XL-Trace Edge Only
6A
Using wire cutters, cut away 1 inch of the braid.
Pull exposed braid back over metal clip.
Using wire cutters, cut away aluminum wrap.
HWAT Only