Instruction Manual
nVent.com/RAYCHEM | 7
Make sure the bus
wires do not kink,
bunch, or crossover.
13
• Push core sealer onto
the heating cable to
the mark made in step
6.
Note: Extra force may
be required for larger
cables or at lower
temperatures.
1/2 in
(13 mm)
1/2 in
(13 mm)
15
• Trim bus wires and braid.
• Repeat steps 12 through 15
for all heating cables.
14
• Remove the guide tubes and
dispose of them in a plastic
bag.
• Slip the green/yellow tube
onto the braid. Heat-shrinking
is not required.
16
Finished view of installed
core sealers.
Optional: Knock
out drain hole
if installed on
bottom of pipe.
11
Tubes
Make sure all strands
go into the tubes.
12
• Slide strain relief
over heating cables,
down onto box nut.
• Secure strain
relief by tightening
screws.
• If needed, re-twist and straighten bus wires,
then insert bus wires into guide tubes as shown.
CAUTION: Health Hazard.
Wash hands after contact with sealant. Consult material
safety data sheet VEN 0058.
Avertissement: risque pour la santé. Se laver les mains
après tout contact avec le produit d’étanchéité.