Product Specifications
FG2-6L FG2-12L FG2-18L FG2-24L
Cable length (ft/m) 6 (1.8) 12 (3.7) 18 (5.5) 24 (7.3)
Min. thermal output on a pipe at 40°F/4°C (watts) 30 60 90 120
Min. thermal output on a pipe at 0°F/–18°C (watts) 46 92 138 184
Max. current draw on a pipe at 40°F/4°C (amps) 0.21 0.43 0.64 0.85
Max. current draw on a pipe at 0°F/–18°C (amps) 0.32 0.64 0.96 1.28
General Specifications for all FG2 Products
Maximum cable width (inch/mm) 0.45 (11.4)
Maximum cable thickness (inch/mm) 0.24 (6.1)
Heating cable bus wire gauge (AWG) 16
Voltage rating (Vac) 208–240
Circuit breaker size 15 A max.
Cold lead length (ft/m) 6 (1.83)
Maximum exposure temperature 150°F (65°C)
Minimum installation temperature 5°F (–15°C)
Minimum bend radius (inch/mm) 5/8 (16)
Electrical classification Nonhazardous areas only
Exposure to chemicals None