MSDS
SECTION 5: FIREFIGHTING MEASURES
Extinguishing media
Extinguishing media:
Extinguish with dry sand and/or flood with large amounts of water.
Extinguishing media which are not suitable: Hand water buckets or hand storage
pumps. Molten metal contact with water can cause small pockets of superheated
steam.
Use fire-extinguishing media appropriate for surrounding materials.
Special hazards arising from the substance or mixture
Specific hazards:
During fire, health hazardous gases may be formed.
Ignition temperature: >1750°F
In the event that the packaging materials are ignited, the immediate and direct
application of large quantities of water will effectively eliminate the spread of fire
to the surrounding areas. The ignition of the packaging materials may, in rare
cases, lead to ignition. Direct application of a continuous heavy stream of water is
recommended.
Ignition of large quantities of exothermic materials may result in large volumes of
dense smoke.
Advice for firefighters
Protective equipment for fire-
fighters:
Selection of respiratory protection for fire fighting: follow the general fire
precautions indicated in the workplace.
SECTION 6: ACCIDENTAL RELEASE MEASURES
Personal precautions, protective equipment and emergency procedures
Personal precautions:
Avoid inhalation of dust. Do not breathe fumes. Avoid contact with skin and eyes.
Follow precautions for safe handling described in this safety data sheet.
Remove sources of ignition. Ventilate well.
Environmental precautions
Environmental
precautions:
Precaution should be taken to prevent hot material and reaction byproducts from
contact with combustible materials in surrounding areas. Avoid spreading dust or
contaminated materials. Avoid discharge to the aquatic environment. Contact
local authorities in case of spillage to drain/aquatic environment.
Methods and material for containment and cleaning up
Spill Cleanup Methods:
Remove sources of ignition. Sweep up spilled substance and remove to safe
place.
For large spills use natural fiber brush or broom with a conductive, non-sparking
pan.
Reference to other sections
References:
For personal protection, see section 8. For waste disposal, see section 13.
Product name:
Supersedes date:
ERICO® CADWELD® Electrical Welding Material
2016-05-02
Page:
Revision:
Version number:
4/13
2016-11-22
US-EN/3.5
CADWELD_EWM_US
SDS-ID:
SAFETY DATA SHEET