Instructions / Assembly

ZN80M
n
ZN110M Installation Guide
Page 5
3
4
1
2
New Construction Installation
5
Connect Wires and Install Knockout Plate
• Run120VACelectricalwiringtotheinstallationlocation.
• UseproperUL-approvedconnectorstosecurewiringtotheKnockoutPlateprovidedinPartsBag.
• Connectwiresasshowninwiringdiagram.
Screw from
Parts Bag
Attach cable clamp to Knockout
Plate. Knockout Plate mounts to
outside of Housing and may be
oriented as desired.
Connect wires
FAN
SENSOR/
CONTROL
BLK
WHT
BLK
ORG
BRN
MASTER MANUAL-ON
GRD
WHT
BLK
GRD
WHT
BLK
BLU
120 VAC
LINE IN
STANDARD OR MULTI-
FUNCTION WALL SWITCHES
RED
14/4
(IF ALL
WALL SWITCH
OPTIONS
ARE USED)
SENSOR/
CONTROL
RED
MASTER
ON/OFF
SWITCH*
MANUAL
ON
SWITCH*
KNOCKOUT
PLATE
RECEPTACLES
120 VAC
LINE IN
SWITCH BOX
BLACK
WHITE
RED
BLUE
*
purchase separately
SENSOR
CONTROL
SWITCH*
GROUND
(green or bare)
ORANGE
BROWN
• SeeOPERATIONsectiononpage12
for details.
• MASTERswitchturnsfansystem
on and shuts it off for fan cleaning and
maintenance purposes.
• SENSOR/CONTROLswitchturns
motion control automatic operation on/off.
• MANUAL-ONswitchdirectlyincreases
fan operation to certified airflow rate.
• MASTERandSENSOR/CONTROL
switches can be combined (see page 10).
• MASTERswitchalongwithorseparate
from SENSOR/CONTROL switch may be
located where it is not easily accessed
for everyday usage; they may need to
be labeled and located where it can’t be
turned on without being seen from fan to
comply with local and national codes.