Instructions / Assembly

ZN80M
n
ZN110M Installation Guide
Page 10
2
1
4
5
6
3
Retrofit Installation
11
Install Knockout Plate, Connect Wires and Install Wiring Panel
Screw from
Parts Bag
Attach cable clamp to Knockout
Plate. Knockout Plate mounts to
inside of Housing and may be
oriented as
desired.
Connect
wires
Screw set
aside in
Step 6
• UseproperUL-approvedconnectorstosecurewiringtotheKnockoutPlateprovidedinPartsBag.
• Connectwiresasshowninwiringdiagram.
FAN
SENSOR/
CONTROL
BLK
WHT
BLK
ORG
MASTER
WALL
SWITCH
GRD
WHT
BLK
GRD
WHT
BLK
BRN
120 VAC
LINE IN
14/2
RED
MASTER
WALL
SWITCH*
KNOCKOUT
PLATE
RECEPTACLES
120 VAC
LINE IN
SWITCH BOX
BLACK
WHITE
*
purchase separately
GROUND
(green or bare)
ORANGE
BROWN
• SeeOPERATIONsectiononpage12
for details.
• MASTERswitchturnsfansystemon
along with motion control and shuts
them off for cleaning and maintenance
purposes.
• MASTERswitchmaybelocated
where it is not easily accessed for
everyday usage; it may need to be
labeled and located where it can’t be
turned on without being seen from
fan to comply with local and national
codes.