Instructions / Assembly

9
WALL INLET INSTALLATION
Model CI370 Wall Inlet (CF361 and CF361F
Rough-In)
1. Remove the cardboard plaster guard.
2. Refer to Figure 20. For some drywall or panel
construction, the plaster frame will extend beyond the
finished wall. In this case, remove plaster frame from
mounting bracket by removing mounting screws.
NOTE: When using the model CF361 and CF361F inlet
bracket on walls thinner than 1⁄2", use a 1⁄4" spacer (not
furnished) between the wall and the inlet bracket. See
Figure 23. Spacer may be made from plywood,
Masonite™, etc. Contact cement may be used to hold
spacer in place during assembly. Configuration of spacer
may vary depending upon installation.
3. Refer to Figure 21. Connect the red striped wire of the
2-conductor low voltage cable to the unused terminal
screw on the inlet. Connect the remaining wire to the
black pigtail wire. Cap off both wires using wire nut (supplied).
NOTE: The LED indicator light used in the CI370 is polarity
sensitive. If the 2-conductor cable used to connect the inlet to
the power unit does not have a polarity marking and the
CI370 is wired backwards, no damage will result; however,
the indicator will light RED instead of GREEN when the hose
is inserted into the inlet. To correct this condition, simply
reverse the 2-conductor connections at the CI370 inlet.
4. Guide excess wire back through the hole in inlet
bracket and flanged fitting
5. Refer to Figure 26. Place inlet into mounting bracket and secure.
NOTE: When wall inlets are installed in walls that are less
than 1⁄2" thick or when inlets are installed back-to-back in
a wall, the tube of the wall inlet may extend into elbow area
of the flanged fitting and cause blockage. Shorten the wall
inlet tube to prevent this condition. Refer to Figure 24.
For extra thick walls, use Model 399 Extension Sleeve to
connect inlet to the flanged fitting.
Model 360 Wall Inlet (CF361 and CF361F
Rough-In)
1. Follow steps 1-2 as above.
2. Refer to Figure 25. Connect 2-conductor low-voltage
wire to terminal screws on back of wall inlet.
3. Follow steps 4-5 above.
Model 330 Wall Inlet (CF329 Rough-In)
See Figure 26
1. Connect 2-conductor low-voltage wire to terminal
screws on back of wall inlet.
2. Align inlet mounting holes with holes in mounting plate.
See Figure 26.
3. Place inlet into mounting plate and secure with two
provided screws. See Figure 26
.
FIGURE 20 FIGURE 21
MOUNTING
PLATE
INLET
FIGURE 25 FIGURE 26
FIGURE 22
2
1
/4"
3
1
/4"
1
/4"
INLET MOUNTING
BRACKET
SPACER
WALL LESS THAN
1
/2" THICK.
PLASTER
GUARD
HOLE
FIGURE 23
FIGURE 24