Instructions / Assembly
IN WALL INSTALLATIONS
Refer to Figure 47.
• ORIGINAL VACPAN can be installed between wall
studs in side walls.
• ORIGINAL VACPAN should be located tight to one
side in stud space.
• Once the ORIGINAL VACPAN location is determined,
cut a 6 ¾” long x 1 ¾” high slot in the wall and
baseboard to accept the ORIGINAL VACPAN.
• The 2 x 4 wall bottom plate between the 2 studs must
be removed. This can be achieved from below using a
hole saw.
• In new home construction, the bottom wall plate can be
removed directly. A 6 ¾” length of 2 x 4 can be used as
a temporary rough in block, that will force all trades to
finish around, leaving a slot for the ORIGINAL VACPAN.
• Floor contractor must run flooring under block.
• Run vacuum tube piping and low voltage wire from
the main line to ORIGINAL VACPAN location.
• Access for final piping connections must be made.
Access from Below
If access is available from below, cut an access
hole through the subfloor underneath the wall
between the studs, positioned so that final piping
connections can be made by reaching through
the access hole.
Access Through Wall
Access can be made through the finished wall.
Cut a 2 ¾” x 3 ½” access hole, positioned so that final
piping connections can be made by reaching through
the access hole. A generic cover plate can be used to
cover the hole after installation (sold separately).
• Attach low voltage wires to ORIGINAL VACPAN
terminal connections marked “low voltage only”.
• Slide ORIGINAL VACPAN into mounting slot and
secure to wall using two #6 screws provided.
• Reach through access hole and make final fitting
connections.
22
FIGURE 47
CF382S