Instructions / Assembly
FLOOR INLET INSTALLATION IN
NEW & EXISTING CONSTRUCTION
Model CI370 or 360 Series Inlets (361 Rough-In)
1. Refer to Figures 41 and 42. After floor inlet location has
been selected, cut a 3
1
⁄16" x 2
9
⁄16" square hole in floor.
Center line of inlet must be located at least 2 ½" from
wall to allow cover to be opened when hose
is inserted.
2. Determine direction of tubing and attach appropriate
flanged fitting to mounting bracket with four (4) screws
supplied. Be sure mounting bracket flange does not
interfere with tubing and seal is securely in place.
3. Refer to Figure 43. Position bracket with frame and
flanged fitting assembly into cutout from below and
secure to sub-floor.
4. Refer to Figure 44. Large end of Model 399 extension
sleeve should be cut to length to allow proper seating
of inlet against floor or carpet.
5. Refer to Figure 45. Pull low-voltage 2-conductor wire
through mounting bracket and attach to terminal
screws on back of floor inlet. Cement extension sleeve
to Model CI370 or 360 inlet. Insert extension sleeve
through vinyl gasket in mounting bracket and firmly
seat into flanged fitting.
6. For convenience of operation, floor inlet should be
installed to open back toward wall.
7. Refer to Figure 43. Secure floor inlet in place with
two screws.
20
MOLDING
WALL
TOP VIEW
2
9
/
16
"
3
1
/16"
FIGURE 41
2
1
/2" MIN.
APPROX.
SIDE VIEW
MOUNTING BRACKET
FLANGE
FIGURE 42
CUT TO
LENGTH
EXTENSION
SLEEVE
FLANGED
FITTING
MOUNTING
BRACKET
FLANGE
FIGURE 44
WALL
INLET
EXTENSION SLEEVE
BRACKETFLANGED FITTING
TUBING
FIGURE 45
FLOOR
SUB-FLOOR
2
9
/16"
3
1
/16"
INLET
EXTENSION
FLOOR
INLET
FRAME
MOUNTING
BRACKET
SEAL
FLANGED
FITTING
FIGURE 43