Warranty
Page 4
VENTILATION FAN / LIGHT MODEL QTXEN150FLT
99045442A
Order service parts by “Part No.” - not by “Key No.”
Replacement parts
can be ordered on our
website. Please visit us
at www.nutone.com
SERVICE PARTS
5. Insert
mask and
finish
ceiling.
Tape mask
into housing.
Mask protects
unit during
construction.
Remove be-
fore installing
grille.
Install ceiling
material. Cut
out around housing.
4. Connect electrical wiring.
Run 120 VAC house wiring to installation lo-
cation. Use proper UL approved connector to
secure house wiring to wiring plate. Connect
wires as shown in wiring diagrams.
WIRNG PLATE & SCREW
FROM PARTS BAG
6. Attach grille to housing.
Plug light into receptacle. Squeeze grille
springs and insert them into tabs on each
side of housing.
8. Remove light lens.
Carefully insert a small flat-blade
screwdriver between grille and lens.
Pry lens out.
7. Push grille against
ceiling.
9. Install light
bulbs.
Product includes
(2) 18W (max.),
type GU24
fluorescent bulbs
with M.O.L.
(maximum overall
length) of 3.9”
(100mm).
Purchase a 4W
incandescent night light bulb. Insert bulbs into their sockets. Replace lens.
3.9" (100mm) M.O.L.
Key No. Part No. Description
1 97020009 Housing
2 97018331 Duct Connector
3 97018721 Parts Bags (includes wiring plate & all screws)
4 97018448 Wire Panel/Harness Assembly
5 97020012 Blower Assembly
6 99140208 Grille Spring (2 req’d)
7 97018533 Grille Assembly (includes key nos. 6 & 8)
8 99111400 Lens
9 99271381 Bulb, GU24, 18W Fluorescent (2 req’d)
10 97018014 Spacer (2 supplied)
11 97020013 Hanger Bar Kit
7
1
2
3
3
3
3
5
4
10
10
11
11
3
6
9
8
SCREW