INSTALLATION INSTRUCTIONS HB0056 NP64000 SERIES ! INTENDED FOR DOMESTIC COOKING ONLY ! READ AND SAVE THESE INSTRUCTIONS INSTALLER: LEAVE THIS MANUAL TO HOMEOWNER. HOMEOWNER: USE AND CARE INFORMATION ON PAGES 11 TO 13 NuTone Inc., 4820 Red Bank Road, Cincinnati, OH 45227 (1-800-543-8687) www.nutone.
! WARNING ! WARNING TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP GREASE FIRE, OBSERVE THE FOLLOWING*: 1. Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer at the address or telephone number listed in the warranty. 1. 2.
- NP64000 SERIES RANGE HOOD SYSTEM INTERIOR BLOWERS Model 634 or 644 (roof cap) Model 647 (7” Rd wall cap) Model 643 (8” Rd wall cap) Model 418 10” round adjustable elbow (optional) Model 415 7” round adjustable elbow (optional) 8” round standard duct Model 407 (7” round 2 ft.
- NP64000 SERIES RANGE HOOD SYSTEM IN-LINE AND EXTERIOR BLOWERS Model 437 (High capacity roof cap) Model 441 Model HLB9 (800 cfm) (10” Rd wall cap) Model 335 (1200 cfm) or HLB11 (1100 cfm) or 336 (1500 cfm) in-line blower Model 331H (600 cfm) exterior blower (includes two 8” x 12” to or 332H (900 cfm) 10’’ round transitions) exterior blower Model 441 (10” Rd wall cap) Model HLB6 (600 cfm) in-line blower (includes two 4½” x 18½” to 10’’ round transitions) Model HLB3 (280 cfm) in-line blower (includes on
1. SELECT BLOWER OPTION AND INSTALL DUCTWORK Either an interior or exterior blower or in-line blower may be used with this hood. The NuTone premier NP64000 Series must be installed with blower models P5, P8, HLB3, HLB6, HLB9, HLB11, 331H, 332H, 335 or 336 only. Other blowers cannot be substituted. (Blowers sold separately). Plan where and how the ductwork will be installed.
2. PREPARE THE INSTALLATION Make sure that the following items are included: - Range hood - Accessories: • Filters • Bag of parts including: (4) lock nuts, (1) wire clamp, (8) 1/2” double thread screws, (2) wire connectors, (2) 1/2” standard screws, (6) 3/8 screws.
5. CHOOSE THE OPENING (INTERIOR BLOWER) Remove the knockout for the chosen opening (horizontal at the back of the hood or vertical on rough-in plate). See pictures below. CAUTION When using P5 blower, remove the 10’’ wide knockout (smaller part). If using P8 blower, remove the knockout corresponding to the ducting installed (10’’ or 14’’).
. INSTALL THE ADAPTER (INTERIOR BLOWER) Using two (2) standard 1/2’’ screws, secure the adapter to the top (or back) of the hood. Seal the adapter to the hood using duct tape. HD0005 HD0006 9. INSTALL THE HOOD (ALL BLOWERS) INTERIOR BLOWER: Run power cable to installation location. Place the hood to its location. Mark the position of the screws (smaller part of the key holes) with a pen. Remove the hood and install the (8) 1/2” double thread screws leaving a 1/8” gap (4 screws for 30” hood).
10. CONNECT WIRING (ALL BLOWERS) ! WARNING Risk of electrical shock. Electrical wiring must be done by qualified personnel in accordance with all applicable codes and standards. Before connecting wires, switch power off at service panel and lock service disconnecting means to prevent power to be switched on accidentally. INTERIOR BLOWER: Connect cable into wiring box using wire connectors. Connect wires as follow: BLACK to BLACK, WHITE to WHITE and GREEN or BARE wire under ground screw.
11. INSTALL THE BLOWER (INTERIOR BLOWER) (CONT’D) Install screws into the location as shown in the pictures below (single blower or dual blower). Do not tighten screws down fully, leave a 1/8” gap. Hang blower unit onto blower plate (screws through the large part of the keyhole). Slide the blower to its position (screws in the small part of the keyhole). Tighten the screws.
12. LIGHT BULBS This range hood uses 50W halogen lamps. (120V, 50W, PAR 20) Install the lamps by rotating them clockwise into their socket holder. 13. HEAT LAMPS The heat lamps required are 120V, 175W max, infrared bulbs. (120V, IR 175W, PAR 38) White halogen lights can be used if warming shelves are not used. (120V, 90W, PAR 38) Install the lamps by rotating them clockwise into their socket holder. 14. INSTALL FILTERS It is recommended to install side filters first and finish with center one(s). 1. 2. 3.
15. USE AND CARE (CONT’D) Hood cleaning Stainless steel cleaning: How to maintain its « BRIGHT LOOK » Do: - Regularly wash surfaces with clean cloth or rag soaked with warm water and mild soap or liquid dish detergent. - Always clean in the direction of original polish lines. - Always rinse well with clear water (2 or 3 times) after cleaning. Wipe dry completely. - You may also use a specialized household stainless steel cleaner.
16. OPERATION (CONT’D) ! WARNING Never place highly flammable material under warming lamps. WARMING LAMPS (INFRARED) Each warming lamp is controlled with its own ON/OFF switch. Use infrared light bulbs (120V, IR175W, PAR38) or white halogen bulbs (120V, 90W, PAR38) if food warming shelves are not used. HEAT SENTRY This hood is equipped with a Heat Sentry thermostat. This thermostat is a device that will turn on or speed up the blower if it senses excessive heat above the cooking surface.
SERVICE PARTS NP64000 Series 1 17 1 19 16 16 18 2 6 11 5 4 12 3 14 15 13 16 16 16 7 1 8 9 10 1 7 HL0073 KEY # 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 PART NUMBER V02264 V02773 V02772 V03435 V03436 V03501 V03507 V03502 V03503 V03504 V03505 V03517 V03518 V03519 V03520 V00673 V02512 V01869 V01582 V00606 V03509 V03510 V13216 V13217 V13218 V13219 V03686 V02544 V03598 V07451 V13278 DESCRIPTION SOCKET LAMP MALE CONNECTOR FEMALE CONNECTOR THERMOSTAT THERMOSTAT BRACKET SPEED CONTROLL
SERVICE PARTS SINGLE BLOWER/ROUGH-IN (Model P5) 1 20 21 2 23 22 19 3 4 17 5 6 8 7 18 16 15 14 13 6 12 9 11 10 HL0021 KEY # 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 PART NUMBER V13296 V03500 V12997 V03577 V02160 V01869 V01857 V01582 V14973 V01810 V03400 V01766 V00871 V02001 V01831 V11705 V11614 V01927 V03495 V03494 V13230 V03496 V00660 V05520 V00613 DESCRIPTION ADAPTER AND DAMPER 31/4’’ x 10’’ AIR DEFLECTOR SINGLE BLOWER ROUGH-IN PLATE ASSEMBLY FOAM 1/2” x 1/2” x 12” CAPACITOR
SERVICE PARTS DUAL BLOWER/ROUGH-IN (Model P8) 2 1 25 3 4 24 23 22 21 5 19 18 17 16 15 14 6 7 8 11 20 9 13 10 12 KEY # 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 PART NUMBER V14971 V13296 V03500 V14975 V03577 V01582 V02160 V01857 V01766 V03400 V14974 V01810 V03399 V03457 V00871 V01831 V11705 V11614 V02001 V01927 V03495 V03494 V14960 V00660 V03496 V05520 V00613 DESCRIPTION ADAPTER AND DAMPER 3 /4” x 14’’ ADAPTER AND DAMPER 31/4” x 10’’ AIR DEFLECTOR DUAL BLOWER ROUGH-IN