Product specifications

Electrified Inlet (with 12 AWG Wire)
NEW HOME INSTALLATION
INSTRUCTIONS
(For Household Use)
1. Fasten the mounting plate to a stud within three
studs (48") of an electrical outlet box. Measure
and mark the wire 10" from the plug (A), Feed
the wire through the top hole in the mounting
plate (Just above the circular opening). Snap the
molded plug into the mounting plate as pictured
(B). This will keep it secure and out of harm’s
way during drywalling and finishing. Line up the
wire at the previously measured 10" mark with
the strain relief channel on the back of the
mounting plate. Secure it in place with the sup-
plied wire tie (C).
2. Run the inlet wire to the adjacent electric box. If
you must run wire through a stud, drill directly
through the center of the stud (D).
3. Place the exposed ends of the two wires into the
electrical box through a strain relief channel (E).
Tighten the strain relief (do not overtighten) on
the white sheathing leaving 1/2" of this sheathing
exposed inside the outlet box.
Fold the 6" of black and white wire into the outlet
box. Leave the wires to be connected by the elec-
trician when plug receptacles are being installed.
(Attention: Power tools such as routers are not
recommended for use with the inlet installation, as
removal of drywall with these devices may cause
damage to the mounting plate and/or inlet plug.)
4. Once drywall and finishing processes have been
completed, remove molded plug from mounting
plate (with the aid of a slot screwdriver) and snap
it into the wing slot at the back of the inlet (F).
(Please note: molded plug fits one way only, with
the narrow opening at the top.) Insert inlet into
mounting plate and secure inlet to mounting plate
with screws provided.
NOTE:
All electrical devices such as the electri-
fied inlet should be reported to the construction
electrician for listing on the inspection report for
building inspection purposes.
NOTE: Plumb inlet to tubing using NuTone
Model 382-S 90° Ell fitting.
®
E
D