7.  Connect wiring.
Connect power cable to housing with appropriate UL 
approved connector. Make wiring connections as shown 
in “Wiring Diagrams” section. Re-install wiring panel and 
secure with screw from parts bag.
9.  Connect 4-in. round duct.
Pull existing ducting through housing discharge 
opening. 
Attach and tape ducting to duct connector. 
Push connector/ducting back through opening. 
Engage tabs and secure with screw from parts 
bag.
Install blower. Finish ceiling, then 
install grille.
See Steps 9 & 10 on Page 6.
8.  Mount fan to ceiling structure.
Mount housing to ceiling structure with standard 
drywall or wood screws in locations shown.
*
Center hole optional.