Installation Guide
INSTALLATION AND USE & CARE INSTRUCTIONS 
INSTALLATION
6
SWITCH BOX
LIGHT
FAN
DUAL CONTROL
(purchase separately)
WHITE
BLACK
RED
GROUND
(bare)
WIRING PLATE
120 VAC LINE IN
RECEPTACLE
(FAN)
RECEPTACLE
(LIGHT)
WIRING DIAGRAM 
7.  Connect wiring.
Connect power cable to housing with appropriate 
UL approved connector (not included). Make wiring 
connections as shown in “Wiring Diagram” section. 
Re-install wiring panel and secure with screw from parts 
bag.
9.  Connect 4-in. round duct.
Pull existing ducting through housing discharge 
opening. 
Attach and tape ducting to duct connector. 
Push connector/ducting back through opening. 
Engage tabs and secure with screw from parts 
bag.
Install blower. Finish ceiling, then 
install grille.
See Steps 9 & 10 on Page 5.
8.  Mount fan to ceiling structure.
Mount housing to ceiling structure with standard 
drywall or wood screws (not included) in locations 
shown.
*
Center hole optional.
1
2
3
4
TABS