Spec Sheet
Broan-NuTone LLC Hartford, Wisconsin www.nutone.com 888-336-3948
REFERENCE QTY. REMARKS Project
Location
Architect
Engineer
Contractor
Submitted by Date
SPECIFICATION SHEET
02B 99045516E
MODEL AERN110L
ROOMSIDE SERIES
FAN / LIGHT
DESCRIPTION
BLOWER:
• Plug-in, permanently lubricated motor - engineered for
continuous operation
• Dynamically balanced centrifugal blower wheel for quiet,
efficient performance
• Low RPM for quiet operation
HOUSING:
• Rugged, 26 gauge, galvanized steel construction
• Polymeric, 4” duct connector with tapered sleeve and no
metallic clatter
• 5-3/4” height allows for 2” x 6” ceiling installations
• Sturdy, easy, four-point mounting directly to joist
• Can be mounted in ceilings up to 7/12 pitch
GRILLE:
• Polymeric construction
• Innovative design - the result of extensive research with
designers and consumers
• 11-Watt integrated LED lighting for energy efficiency
• 3000K color temperature provides soft white light - ideal
for bathroom illumination
• LED lasts up to 25,000 hours for maintenance-free
convenience
CONTROLS (Purchase separately):
• Refer to NuTone’s catalog for a complete line of
accessories to effectively adapt these fans to your
construction requirements.
DIMMING CONTROLS:
• May not be compatible with all dimmer controls
• Each application is unique and various factors such as
load, common neutrals or other electrical products on
the circuit can, in certain instances, cause variance in
system performance.
• Dimmer model numbers vary slightly depending on color,
packaging type, etc. such that variations of Model numbers
may be suitable. Consult dimming system manufacturer for
additional support in operation
* For a list of compatible controls, see NuTone.com
U.L. Listed for use over bathtubs and showers when
connected to a GFCI protected branch circuit (ceiling mount
only).
U.L. Listed for use in insulated ceilings (TYPE I.C.)
3-Year Warranty.
TYPICAL SPECIFICATION
Fan / Light shall be NuTone Model AERN110L.
Fan / Light shall have corrosion resistant galvanized steel
housing with four-point mounting capability. It shall be ducted
to a roof or wall cap using 4” round ductwork.
Blower assembly shall be removable, have a centrifugal-type
blower wheel and a permanently lubricated motor designed
for continuous operation.
Non-metallic damper/duct connector shall be included.
LED module shall be 11-Watt with 3000K color temperature
and 800 lumen output (min.).
Air delivery shall be no less than the airflow values and
no greater than the sound level values listed in the HVI
Performance Specifications provided in this specification
(see following chart). All air and sound ratings shall be
certified by HVI.
Ceiling Ventilator shall be U.L. Listed for use in insulated
ceilings (Type I.C.) and for use over bathtubs and showers
when connected to a GFCI protected branch circuit.
JA8-2019