Specification
Broan Hartford, Wisconsin www.nutone.com 888-336-3948
REFERENCE QTY. REMARKS Project
Location
Architect
Engineer
Contractor
Submitted by Date
SPECIFICATION SHEET
81K 1100253B
MODEL AERN110DCSL
FLEX DC
TM
SERIES
HUMIDITY SENSING FAN / LIGHT
A modern-styled, high performance fan, with sensing circuitry,
that "knows" when to ventilate the room.
FEATURES
BLOWER:
• Plug-in, permanently lubricated, brushless DC motor -
engineered for continuous operation
• Dynamically balanced centrifugal blower wheel for quiet,
efficient performance
• Low RPM for quiet operation
HOUSING:
• Rugged, 26 gauge, galvanized steel construction
• Polymeric, 4” damper / duct connector with tapered sleeve and
no metallic clatter
• 5-3/4” height allows for 2” x 6” ceiling installations
• Sturdy, easy, four-point mounting directly to joist
• Optional snap-on flange kit
GRILLE:
• Polymeric construction
• Innovative design - the result of extensive research with
designers and consumers
• 11-Watt integrated LED lighting for energy efficiency
• 3500K color temperature provides soft white light - ideal for
bathroom illumination
• LED lasts up to 25,000 hours for maintenance-free
convenience
DIMMING CONTROLS :
• For a list of compatible dimming controls, see the RESOURCES
link for Model AERN110DCSL at
www.nutone.com
• Each application is unique and various factors such as load,
common neutrals or other electrical products on the circuit can,
in certain instances, cause variance in system performance
• Dimmer model numbers vary slightly depending on color,
packaging type, etc. such that variations of model numbers
may be suitable. Consult dimming system manufacturer for
additional support in operation
AUTOMATIC CONTROL:
• Humidity control automatically turns fan ON when
either of these conditions is detected:
- a rapid to moderate (user adjustable) increase of
humidity
- humidity above user-adjustable set-point (50%-
80% RH)
• Two wire manual operation for odor control - Turns
fan ON when power line through wall switch is
cycled ON, OFF and back ON
• Remains ON for a user-adjustable 5 to 60 minutes
after humidity has stabilized and is below set-point
or after manually initiated through power line cycling
• Saves energy because unit runs only for the time
required. A unit controlled with a wall timer may
keep fan ON longer than required or turn it OFF
before room is sufficiently ventilated
U.L. Listed for use over bathtubs and showers when
connected to a GFCI protected branch circuit (ceiling
mount only)
U.L. Listed for use in insulated ceilings (Type I.C.)
3-Year Warranty
JA8-2019